
CMK-63 Transparent Lever Connectors
4 models · 450 V AC · 32 A
CMK-632 · CMK-633 · CMK-634 · CMK-635
Compare models & specificationsChoose by conductor.
Connect with the right model.
Compare lever splices, rigid-wire push-in connectors, inline branches, DIN rail terminals and lighting connectors. Model tables keep wire ranges, ratings and preparation dimensions together.
Browse all families Compare wire ranges →For flexible equipment leads, start with a lever or lighting connection that lists a flexible-wire range. For rigid wiring, compare the push-in families. Use an inline or DIN rail format when the wiring arrangement calls for it.
| Family & model selection | Electrical arrangement | Rigid wire (mm²) | Flexible wire (mm²) | Strip length |
|---|---|---|---|---|
| CMK-63 →Lever connectors | Common-potential splice | 0.5–4 | 0.5–2.5 | 11 mm |
| CMK-61 →Lever connectors | Common-potential splice | 0.75–2.5 | 1.0–2.5 | 13 mm |
| CMK-25 →Push-in connectors | Common-potential splice | 0.75–2.5 | Rigid wire only | 11 mm |
| CMK-41 →Lever connectors | Common-potential splice | 0.2–4 | 0.08–2.5 | 11 mm |
| CMK-42 →Inline connectors | Inline or branch arrangement, selected by model | 0.2–4 | 0.08–2.5 | 11 mm |
| CMK-420 →DIN rail terminals | Two-entry through terminal | 0.2–4 | 0.08–2.5 | 11 mm |
| CMK-20 →Push-in connectors | Common-potential splice | 0.5–2.5 | Rigid wire only | 11 mm |
| CMK-10 →Push-in connectors | Common-potential splice | 1.0–2.5; CMK-123: 1.5–6 | Rigid wire only | 11 mm |
| CMK lighting →Lighting connectors | Lighting inline connection | 0.5–2.5 | 1.0–2.5 | 11 mm |
| CMK823 →Lighting connectors | Multi-position spring terminal block | 0.2–6 by model | 0.2–6 by model | 11 mm |
Wire ranges refer to copper cross-section, not insulation diameter. CMK-10 and CMK823 include model-specific ranges: use the complete model row for the final selection. A conductor entry is not necessarily an electrically separate circuit. On smaller screens, swipe the table to compare all columns.
Search an exact model, such as CMK-413 or CMK823-2.5/12, or filter by connection type.
10 families · 52 connector models

4 models · 450 V AC · 32 A
CMK-632 · CMK-633 · CMK-634 · CMK-635
Compare models & specifications
4 models · 450 V AC · 32 A
CMK-612 · CMK-613 · CMK-614 · CMK-615
Compare models & specifications8 models · 450 V AC · 24 A
CMK-252 · CMK-252X · CMK-253 · CMK-253X · CMK-254 · CMK-254X · CMK-255 · CMK-255X
Compare models & specifications4 models · 450 V AC · 32 A
CMK-412 · CMK-413 · CMK-414 · CMK-415
Compare models & specifications9 models · 450 V AC · 32 A
CMK-401 · CMK-422 · CMK-423 · CMK-424 · CMK-425 · CMK-422-4 · CMK-422-6 · CMK-421-2 · CMK-421-3
Compare models & specifications
2 models · 450 V AC · 32 A
CMK-420 · CMK-420J
Compare models & specifications
6 models · 450 V AC · 24 A
CMK-202 · CMK-203 · CMK-204 · CMK-205 · CMK-206 · CMK-208
Compare models & specifications5 models · 450 V AC · 24 A
CMK-102 · CMK-104 · CMK-106 · CMK-108 · CMK-123
Compare models & specifications
3 models · 450 V AC · 24 A
CMK-101 · CMK-112 · CMK-201
Compare models & specifications
7 models · 450 V AC · 5 / 10 / 25 A
CMK823-1.5/2 · CMK823-1.5/3 · CMK823-2.5/2 · CMK823-2.5/3 · CMK823-6/2 · CMK823-6/3 · CMK823-2.5/12
Compare models & specificationsNo matching connector. Try a shorter model code or clear the type filter.
Match the conductor construction and cross-section, required electrical arrangement, port count and current rating. Then check stripping length and the available space in the enclosure. Port count alone does not identify electrically separate circuits.
Lever connectors open the spring clamp for insertion and removal, with separate rigid and flexible wire ranges. The push-in models listed here are selected for rigid conductors and have no individual release levers.
No. These ranges include 5 A, 10 A, 24 A, 25 A and 32 A models. CMK823 ratings change with the conductor-size class. Use the rating for the complete model code.
These are wiring components for installation inside a suitable enclosure. A connector housing is not a substitute for the environmental protection and strain relief of a junction box.
List each model, quantity, conductor type and cross-section, destination and packaging requirements. For a branch or DIN rail assembly, also specify the required connection arrangement and accessories.
Include model codes, quantities, conductor sizes, destination and packaging requirements.