Lever connectors

CMK-63 Transparent Lever Connectors

CMK-632, CMK-633, CMK-634 and CMK-635 join two to five conductors on one common electrical potential. A transparent housing makes the insertion depth visible, while individual red levers release each conductor for servicing.

450 V AC32 A4 models
CMK-63 Transparent Lever Connectors product examples
CMK-63 Transparent Lever Connectors
Technical data

Electrical & connection specifications

CMK-63 Transparent Lever Connectors — series specifications
ParameterSpecification
Rated voltage450 V AC
Rated current32 A
Rigid conductor range0.5–4 mm²
Flexible conductor range0.5–2.5 mm²
Strip length11 mm
Operating temperature−40 to +105 °C
Housing materialTransparent polycarbonate (PC)
Conductive partsTin-plated copper
Contact springAISI 301 stainless steel
Connection arrangementCommon-potential splice
Lever materialPOM (polyacetal)

Ratings apply to the listed connector configuration. The permissible circuit current also depends on conductor size, installation conditions and circuit protection. Use copper conductors.

Models & ordering

Choose the complete model code

Each model below has its own conductor-entry count. Electrical ratings are not multiplied by the number of entries.

CMK-63 Transparent Lever Connectors — model selection
ModelConductor entriesInner pack (pcs)Carton (pcs)
CMK-63221006000
CMK-63331004000
CMK-63441004000
CMK-63551004000

4 models

Pack quantities describe standard packaging, not minimum order quantities. State the required quantity for each model in your inquiry.

Mechanical dimensions

Dimensions in millimetres

CMK-63 Transparent Lever Connectors — housing dimensions
ModelDepth (mm)Width (mm)Height (mm)
CMK-63219.215.510.3
CMK-63319.221.810.3
CMK-63519.234.410.3
Application & installation

Match the wire and the electrical path

Choose the port count for conductors that must share the same potential. Use separate connectors for line, neutral and protective earth. The flexible-wire range is smaller than the rigid-wire range.

Application fit

  • Junction-box conductor splicing
  • Lighting distribution within an enclosure
  • Serviceable equipment wiring

Preparation & connection

  1. Isolate the circuit and verify that it is de-energised.
  2. Use a conductor within the specified range; strip 11 mm without damaging the copper.
  3. Open the operating lever or spring tab, insert the conductor to the stop, then release or close the actuator.
  4. Use one conductor per entry. Check that no bare copper is exposed and gently pull each wire to check retention.
  5. Arrange the connector in an enclosure with appropriate wire support, then verify the intended circuit before energising.
Practical answers

Frequently asked questions

Are all ports connected together?

Yes. CMK-632 to CMK-635 are common-potential splicing connectors; the port count is not a count of isolated circuits.

Can a 4 mm² flexible wire be used?

The specified flexible-wire range is 0.5–2.5 mm². The 4 mm² maximum applies to rigid wire.

What is the strip length?

Strip 11 mm of insulation, open the lever, insert the conductor fully and close the lever.