30 mm enclosed format
LRS Low-Profile Power Supplies
Single-output AC/DC supplies in a 30 mm-high metal case. Compare 35–450 W series classes, then select the output voltage and rated current for the load.
Compare this family →CHSO / INDUSTRIAL POWER
Compare CHSO LRS, S, HLW, NDR and EDR AC/DC power supplies. Select output voltage and current, check case dimensions, and prepare a model-specific enquiry.
42 series classes · 156 output versions
01 / PRODUCT FAMILIES
30 mm enclosed format
Single-output AC/DC supplies in a 30 mm-high metal case. Compare 35–450 W series classes, then select the output voltage and rated current for the load.
Compare this family →15–1200 W series classes
Chassis-mounted AC/DC supplies for equipment and control panels. The range includes low-power wide-input models, switch-selectable input models and 180–264 VAC high-power models.
Compare this family →1200–4000 W series classes
High-power supplies with adjustable voltage and current control. Choose a 0–24 V, 0–36 V or 0–48 V output range, then specify the required voltage and current operating point.
Compare this family →75 / 120 / 240 / 480 W
Metal-case DIN rail supplies for control-cabinet DC distribution. Compare rail width, output current and input range before allocating space in the panel.
Compare this family →75 / 120 / 150 W
DIN rail AC/DC supplies with 12 V, 24 V and 48 V versions. Select by continuous current, enclosure temperature and the space available on the rail.
Compare this family →MODEL SELECTION
156 output versions
Series class identifies the family. Use the exact voltage/current row for sizing. HLW voltage filters refer to maximum output voltage. Scroll the table horizontally on smaller screens.
| Model | Output (VDC) | Rated current (A) | Series class (W) | AC input | Case dimensions (mm) | Enquiry |
|---|---|---|---|---|---|---|
| LRS-35-5 | 5 | 7 | 35 | 85–264 VAC | 99 × 82 × 30 mmL × W × H | |
| LRS-35-12 | 12 | 3 | 35 | 85–264 VAC | 99 × 82 × 30 mmL × W × H | |
| LRS-35-24 | 24 | 1.5 | 35 | 85–264 VAC | 99 × 82 × 30 mmL × W × H | |
| LRS-35-48 | 48 | 0.8 | 35 | 85–264 VAC | 99 × 82 × 30 mmL × W × H | |
| LRS-50-5 | 5 | 10 | 50 | 85–264 VAC | 99 × 82 × 30 mmL × W × H | |
| LRS-50-12 | 12 | 4.2 | 50 | 85–264 VAC | 99 × 82 × 30 mmL × W × H | |
| LRS-50-24 | 24 | 2.2 | 50 | 85–264 VAC | 99 × 82 × 30 mmL × W × H | |
| LRS-50-48 | 48 | 1.1 | 50 | 85–264 VAC | 99 × 82 × 30 mmL × W × H | |
| LRS-75-5 | 5 | 14 | 75 | 85–264 VAC | 99 × 97 × 30 mmL × W × H | |
| LRS-75-12 | 12 | 6 | 75 | 85–264 VAC | 99 × 97 × 30 mmL × W × H | |
| LRS-75-24 | 24 | 3.2 | 75 | 85–264 VAC | 99 × 97 × 30 mmL × W × H | |
| LRS-75-48 | 48 | 1.6 | 75 | 85–264 VAC | 99 × 97 × 30 mmL × W × H | |
| LRS-100-5 | 5 | 18 | 100 | 85–264 VAC | 129 × 97 × 30 mmL × W × H | |
| LRS-100-12 | 12 | 8.5 | 100 | 85–264 VAC | 129 × 97 × 30 mmL × W × H | |
| LRS-100-24 | 24 | 4.5 | 100 | 85–264 VAC | 129 × 97 × 30 mmL × W × H | |
| LRS-100-48 | 48 | 2.3 | 100 | 85–264 VAC | 129 × 97 × 30 mmL × W × H | |
| LRS-120-5 | 5 | 20 | 120 | 85–264 VAC | 129 × 97 × 30 mmL × W × H | |
| LRS-120-12 | 12 | 10 | 120 | 85–264 VAC | 129 × 97 × 30 mmL × W × H | |
| LRS-120-24 | 24 | 5 | 120 | 85–264 VAC | 129 × 97 × 30 mmL × W × H | |
| LRS-120-48 | 48 | 2.5 | 120 | 85–264 VAC | 129 × 97 × 30 mmL × W × H | |
| LRS-150-12 | 12 | 12.5 | 150 | 90–132 / 180–264 VAC; select with input switch | 159 × 97 × 30 mmL × W × H | |
| LRS-150-24 | 24 | 6.5 | 150 | 90–132 / 180–264 VAC; select with input switch | 159 × 97 × 30 mmL × W × H | |
| LRS-150-36 | 36 | 4.3 | 150 | 90–132 / 180–264 VAC; select with input switch | 159 × 97 × 30 mmL × W × H | |
| LRS-150-48 | 48 | 3.3 | 150 | 90–132 / 180–264 VAC; select with input switch | 159 × 97 × 30 mmL × W × H | |
| LRS-200-12 | 12 | 17 | 200 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-200-24 | 24 | 8.8 | 200 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-200-36 | 36 | 5.9 | 200 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-200-48 | 48 | 4.4 | 200 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-350-12 | 12 | 29 | 350 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-350-24 | 24 | 14.6 | 350 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-350-36 | 36 | 9.7 | 350 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-350-48 | 48 | 7.3 | 350 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-400-12 | 12 | 33 | 400 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-400-24 | 24 | 16.7 | 400 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-400-36 | 36 | 11 | 400 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-400-48 | 48 | 8.5 | 400 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-450-12 | 12 | 37.5 | 450 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-450-24 | 24 | 18.8 | 450 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-450-36 | 36 | 12.5 | 450 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-450-48 | 48 | 9.4 | 450 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| S-15-5 | 5 | 3 | 15 | 85–264 VAC | 99 × 97 × 35 mmL × W × H | |
| S-15-12 | 12 | 1.3 | 15 | 85–264 VAC | 99 × 97 × 35 mmL × W × H | |
| S-15-15 | 15 | 1 | 15 | 85–264 VAC | 99 × 97 × 35 mmL × W × H | |
| S-15-24 | 24 | 0.7 | 15 | 85–264 VAC | 99 × 97 × 35 mmL × W × H | |
| S-25-5 | 5 | 5 | 25 | 85–264 VAC | 99 × 97 × 35 mmL × W × H | |
| S-25-12 | 12 | 2.1 | 25 | 85–264 VAC | 99 × 97 × 35 mmL × W × H | |
| S-25-15 | 15 | 1.7 | 25 | 85–264 VAC | 99 × 97 × 35 mmL × W × H | |
| S-25-24 | 24 | 1.1 | 25 | 85–264 VAC | 99 × 97 × 35 mmL × W × H | |
| S-35-5 | 5 | 7 | 35 | 85–264 VAC | 129 × 98 × 38 mmL × W × H | |
| S-35-12 | 12 | 3 | 35 | 85–264 VAC | 129 × 98 × 38 mmL × W × H | |
| S-35-15 | 15 | 2.4 | 35 | 85–264 VAC | 129 × 98 × 38 mmL × W × H | |
| S-35-24 | 24 | 1.5 | 35 | 85–264 VAC | 129 × 98 × 38 mmL × W × H | |
| S-50-5 | 5 | 10 | 50 | 90–132 / 180–264 VAC; select with input switch | 159 × 98 × 38 mmL × W × H | |
| S-50-12 | 12 | 4.2 | 50 | 90–132 / 180–264 VAC; select with input switch | 159 × 98 × 38 mmL × W × H | |
| S-50-15 | 15 | 3.3 | 50 | 90–132 / 180–264 VAC; select with input switch | 159 × 98 × 38 mmL × W × H | |
| S-50-24 | 24 | 2.2 | 50 | 90–132 / 180–264 VAC; select with input switch | 159 × 98 × 38 mmL × W × H | |
| S-60-12 | 12 | 5 | 60 | 90–132 / 180–264 VAC; select with input switch | 159 × 98 × 38 mmL × W × H | |
| S-60-15 | 15 | 4 | 60 | 90–132 / 180–264 VAC; select with input switch | 159 × 98 × 38 mmL × W × H | |
| S-60-24 | 24 | 2.5 | 60 | 90–132 / 180–264 VAC; select with input switch | 159 × 98 × 38 mmL × W × H | |
| S-75-12 | 12 | 6.3 | 75 | 90–132 / 180–264 VAC; select with input switch | 159 × 98 × 38 mmL × W × H | |
| S-75-15 | 15 | 5 | 75 | 90–132 / 180–264 VAC; select with input switch | 159 × 98 × 38 mmL × W × H | |
| S-75-24 | 24 | 3 | 75 | 90–132 / 180–264 VAC; select with input switch | 159 × 98 × 38 mmL × W × H | |
| S-100-5 | 5 | 20 | 100 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-100-12 | 12 | 8.5 | 100 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-100-15 | 15 | 6.7 | 100 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-100-24 | 24 | 4.5 | 100 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-100-48 | 48 | 2 | 100 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-120-5 | 5 | 22 | 120 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-120-12 | 12 | 10 | 120 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-120-15 | 15 | 8 | 120 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-120-24 | 24 | 5 | 120 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-120-48 | 48 | 2.5 | 120 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-145-5 | 5 | 25 | 145 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-145-7.5 | 7.5 | 18 | 145 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-145-12 | 12 | 12 | 145 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-145-24 | 24 | 6 | 145 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-150-5 | 5 | 30 | 150 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-150-12 | 12 | 12.5 | 150 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-150-15 | 15 | 10 | 150 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-150-24 | 24 | 6.5 | 150 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-150-48 | 48 | 3.2 | 150 | 90–132 / 180–264 VAC; select with input switch | 199 × 98 × 38 mmL × W × H | |
| S-200-5 | 5 | 40 | 200 | 90–132 / 180–264 VAC; select with input switch | 199 × 110 × 50 mmL × W × H | |
| S-200-12 | 12 | 16 | 200 | 90–132 / 180–264 VAC; select with input switch | 199 × 110 × 50 mmL × W × H | |
| S-200-15 | 15 | 13.3 | 200 | 90–132 / 180–264 VAC; select with input switch | 199 × 110 × 50 mmL × W × H | |
| S-200-24 | 24 | 8.3 | 200 | 90–132 / 180–264 VAC; select with input switch | 199 × 110 × 50 mmL × W × H | |
| S-200-48 | 48 | 4.2 | 200 | 90–132 / 180–264 VAC; select with input switch | 199 × 110 × 50 mmL × W × H | |
| S-240-12 | 12 | 20 | 240 | 90–132 / 180–264 VAC; select with input switch | 199 × 110 × 50 mmL × W × H | |
| S-240-24 | 24 | 10 | 240 | 90–132 / 180–264 VAC; select with input switch | 199 × 110 × 50 mmL × W × H | |
| S-240-36 | 36 | 6.7 | 240 | 90–132 / 180–264 VAC; select with input switch | 199 × 110 × 50 mmL × W × H | |
| S-240-48 | 48 | 5 | 240 | 90–132 / 180–264 VAC; select with input switch | 199 × 110 × 50 mmL × W × H | |
| S-250-12 | 12 | 20 | 250 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 50 mmL × W × H | |
| S-250-15 | 15 | 16 | 250 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 50 mmL × W × H | |
| S-250-24 | 24 | 10 | 250 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 50 mmL × W × H | |
| S-250-48 | 48 | 5 | 250 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 50 mmL × W × H | |
| S-350-5 | 5 | 50 | 350 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 50 mmL × W × H | |
| S-350-12 | 12 | 29 | 350 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 50 mmL × W × H | |
| S-350-24 | 24 | 14.6 | 350 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 50 mmL × W × H | |
| S-350-48 | 48 | 7.3 | 350 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 50 mmL × W × H | |
| S-400-5 | 5 | 55 | 400 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 50 mmL × W × H | |
| S-400-12 | 12 | 33.3 | 400 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 50 mmL × W × H | |
| S-400-24 | 24 | 16.6 | 400 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 50 mmL × W × H | |
| S-400-48 | 48 | 8.3 | 400 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 50 mmL × W × H | |
| S-500-12V | 12 | 40 | 500 | 180–264 VAC | 234 × 124 × 64 mmL × W × H | |
| S-500-24V | 24 | 20 | 500 | 180–264 VAC | 234 × 124 × 64 mmL × W × H | |
| S-500-36V | 36 | 13.9 | 500 | 180–264 VAC | 234 × 124 × 64 mmL × W × H | |
| S-500-48V | 48 | 10 | 500 | 180–264 VAC | 234 × 124 × 64 mmL × W × H | |
| S-600-12V | 12 | 50 | 600 | 180–264 VAC | 234 × 124 × 64 mmL × W × H | |
| S-600-24V | 24 | 25 | 600 | 180–264 VAC | 234 × 124 × 64 mmL × W × H | |
| S-600-36V | 36 | 16.7 | 600 | 180–264 VAC | 234 × 124 × 64 mmL × W × H | |
| S-600-48V | 48 | 12.5 | 600 | 180–264 VAC | 234 × 124 × 64 mmL × W × H | |
| S-1000-12 | 12 | 83 | 1000 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| S-1000-13.5 | 13.5 | 74 | 1000 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| S-1000-15 | 15 | 67 | 1000 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| S-1000-24 | 24 | 41.7 | 1000 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| S-1000-36 | 36 | 28 | 1000 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| S-1000-48 | 48 | 21 | 1000 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| S-1200-24 | 24 | 50 | 1200 | 180–264 VAC | 291 × 132 × 64 mmL × W × H | |
| S-1200-36 | 36 | 33 | 1200 | 180–264 VAC | 291 × 132 × 64 mmL × W × H | |
| S-1200-48 | 48 | 25 | 1200 | 180–264 VAC | 291 × 132 × 64 mmL × W × H | |
| HLW-1200-(0-24) | 0–24 | 50 | 1200 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1200-(0-36) | 0–36 | 33 | 1200 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1200-(0-48) | 0–48 | 25 | 1200 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1500-(0-24) | 0–24 | 62.5 | 1500 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1500-(0-36) | 0–36 | 42 | 1500 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1500-(0-48) | 0–48 | 31 | 1500 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1800-(0-24) | 0–24 | 75 | 1800 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1800-(0-36) | 0–36 | 50 | 1800 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1800-(0-48) | 0–48 | 37.5 | 1800 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-2000-(0-24) | 0–24 | 80 | 2000 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-2000-(0-36) | 0–36 | 55 | 2000 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-2000-(0-48) | 0–48 | 42 | 2000 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-3000-(0-24) | 0–24 | 125 | 3000 | 180–264 VAC | 285 × 185 × 70 mmL × W × H | |
| HLW-3000-(0-36) | 0–36 | 83 | 3000 | 180–264 VAC | 285 × 185 × 70 mmL × W × H | |
| HLW-3000-(0-48) | 0–48 | 62.5 | 3000 | 180–264 VAC | 285 × 185 × 70 mmL × W × H | |
| HLW-4000-(0-24) | 0–24 | 167 | 4000 | 180–264 VAC | 315 × 208 × 73 mmL × W × H | |
| HLW-4000-(0-36) | 0–36 | 111 | 4000 | 180–264 VAC | 315 × 208 × 73 mmL × W × H | |
| HLW-4000-(0-48) | 0–48 | 83 | 4000 | 180–264 VAC | 315 × 208 × 73 mmL × W × H | |
| NDR-75-12 | 12 | 6.3 | 75 | 85–264 VAC | 32 × 125.2 × 102 mmW × H × D | |
| NDR-75-24 | 24 | 3.2 | 75 | 85–264 VAC | 32 × 125.2 × 102 mmW × H × D | |
| NDR-75-48 | 48 | 1.6 | 75 | 85–264 VAC | 32 × 125.2 × 102 mmW × H × D | |
| NDR-120-12 | 12 | 10 | 120 | 85–264 VAC | 40 × 125.2 × 113.5 mmW × H × D | |
| NDR-120-24 | 24 | 5 | 120 | 85–264 VAC | 40 × 125.2 × 113.5 mmW × H × D | |
| NDR-120-48 | 48 | 2.5 | 120 | 85–264 VAC | 40 × 125.2 × 113.5 mmW × H × D | |
| NDR-240-24 | 24 | 10 | 240 | 85–264 VAC | 63 × 125.2 × 113.5 mmW × H × D | |
| NDR-240-48 | 48 | 5 | 240 | 85–264 VAC | 63 × 125.2 × 113.5 mmW × H × D | |
| NDR-480-24 | 24 | 20 | 480 | 100–240 VAC | 85.5 × 125.2 × 128.5 mmW × H × D | |
| NDR-480-48 | 48 | 10 | 480 | 100–240 VAC | 85.5 × 125.2 × 128.5 mmW × H × D | |
| EDR-75-12 | 12 | 6.3 | 75 | 85–264 VAC | 32 × 125.2 × 102 mmW × H × D | |
| EDR-75-24 | 24 | 3.2 | 75 | 85–264 VAC | 32 × 125.2 × 102 mmW × H × D | |
| EDR-75-48 | 48 | 1.6 | 75 | 85–264 VAC | 32 × 125.2 × 102 mmW × H × D | |
| EDR-120-12 | 12 | 10 | 120 | 85–264 VAC | 40 × 125.2 × 113.5 mmW × H × D | |
| EDR-120-24 | 24 | 5 | 120 | 85–264 VAC | 40 × 125.2 × 113.5 mmW × H × D | |
| EDR-120-48 | 48 | 2.5 | 120 | 85–264 VAC | 40 × 125.2 × 113.5 mmW × H × D | |
| EDR-150-12 | 12 | 12.5 | 150 | 85–264 VAC | 40 × 125 × 113.5 mmW × H × D | |
| EDR-150-24 | 24 | 6.25 | 150 | 85–264 VAC | 40 × 125 × 113.5 mmW × H × D | |
| EDR-150-48 | 48 | 3.1 | 150 | 85–264 VAC | 40 × 125 × 113.5 mmW × H × D |
No matching output version. Reduce the current filter or choose another voltage.
INSTALLATION & LOAD CHECK
Disconnect the supply before wiring or changing the input selector. Connect protective earth to the marked FG/PE terminal. Keep ventilation openings clear and use the selected model drawing for mounting. Capacitive, motor and pulsed loads require a start-up and transient-load check.
SELECTION SUPPORT
Match the DC voltage first. Add the continuous currents of the loads and account for start-up demand, operating duty and cabinet temperature. Check the exact output-version current; the series-class wattage alone is not a sizing value.
Repeated +V and −V terminals on a single-output supply belong to the same output. They do not create independent channels. Check the terminal drawing and permitted current per terminal.
The rated current remains a limit when voltage is reduced. When voltage is increased, current may need to be reduced to remain within the permitted output power. Confirm the operating point and derating curve.
Send the complete model, output voltage, continuous and start-up current, mains voltage, quantity, cabinet temperature and available space. Include the documents, sample or mounting drawing needed for approval.
MODEL-SPECIFIC ENQUIRY
Select models from the table, then enter quantities and application details. Copy the request into your message to CHSO.
Contact CHSO →Preparing this list does not send a message.