PRIVATE DESIGN PREVIEW Product data and supply terms are being verified. RFQ lists stay in this browser.
Wenzhou Changsong Electric Co., Ltd.
Catalogs & technical filesContact & inquiryEN
CHSOINDUSTRIAL ELECTRICALRequest a quote 0→
Products/Power Supplies/S

CHSO / INDUSTRIAL POWER

S-500 Enclosed Power Supplies

S-500 single-output enclosed AC/DC power supplies. 12 V / 40 A, 24 V / 20 A, 36 V / 13.9 A, 48 V / 10 A. Case: 234 × 124 × 64 mm (L × W × H).

180–264 VAC · 4 output versions

S-500 AC/DC power supply
S-500 / 234 × 124 × 64 mm / L × W × H

MODEL SELECTION

Match voltage and current.

Download selection table · CSV ↓

4 output versions

Series class identifies the family. Use the exact voltage/current row for sizing. HLW voltage filters refer to maximum output voltage. Scroll the table horizontally on smaller screens.

Output ratings and case dimensions
ModelOutput (VDC)Rated current (A)Series class (W)AC inputCase dimensions (mm)Enquiry
S-500-12V1240500180–264 VAC234 × 124 × 64 mmL × W × H
S-500-24V2420500180–264 VAC234 × 124 × 64 mmL × W × H
S-500-36V3613.9500180–264 VAC234 × 124 × 64 mmL × W × H
S-500-48V4810500180–264 VAC234 × 124 × 64 mmL × W × H

ELECTRICAL DATA

S-500 specifications

S-500 — output characteristics
ModelRipple & noise (mVp-p, max.)EfficiencyLine regulationLoad regulationVoltage adjustment
S-500-12V7584%±0.5%±0.5%±10%
S-500-24V10085%±0.5%±0.5%±10%
S-500-36V10084%±0.5%±0.5%±10%
S-500-48V12087%±0.5%±0.5%±10%

Efficiency is the listed model value; operating conditions affect actual efficiency. Ripple/noise comparison requires the same measurement bandwidth and probe method.

S-500 — input, environment and protection
ParameterSpecification
AC input180–264 VAC
DC input240–370 VDC
Operating ambient−10 to +60 °C
Humidity20–90% RH; non-condensing installation
Overload protection110–150%; hiccup protection, automatic recovery after fault removal
Overvoltage protectionOutput shutdown; confirm reset sequence for the selected version
MountingChassis mounting; use the matched mounting-hole drawing
Overall dimensions234 × 124 × 64 mm (L × W × H)

MECHANICAL FIT

Dimensions and terminal layout

234 × 124 × 64 mm (L × W × H). Allow additional room for wiring and airflow.

S-500 dimensional drawing in mm
S-500 · dimensions in mm · Open full drawing ↗

Read terminal markings on the selected unit. L/N are AC input; FG/PE is protective earth; +V/−V are DC output. Terminal numbering and the number of parallel terminals vary by model.

Selection notes

INSTALLATION & LOAD CHECK

Check the complete operating condition.

01

Mains voltage and input selector

02

Continuous current and start-up demand

03

Cabinet temperature and airflow

04

Mounting holes, terminals and protective earth

Disconnect the supply before wiring or changing the input selector. Connect protective earth to the marked FG/PE terminal. Keep ventilation openings clear and use the selected model drawing for mounting. Capacitive, motor and pulsed loads require a start-up and transient-load check.

SELECTION SUPPORT

Questions before ordering

How do I size a power supply for a load?

Match the DC voltage first. Add the continuous currents of the loads and account for start-up demand, operating duty and cabinet temperature. Check the exact output-version current; the series-class wattage alone is not a sizing value.

Can several output terminals supply separate voltages?

Repeated +V and −V terminals on a single-output supply belong to the same output. They do not create independent channels. Check the terminal drawing and permitted current per terminal.

Does an adjustable output retain the same power at every voltage?

The rated current remains a limit when voltage is reduced. When voltage is increased, current may need to be reduced to remain within the permitted output power. Confirm the operating point and derating curve.

What should I include in an enquiry?

Send the complete model, output voltage, continuous and start-up current, mains voltage, quantity, cabinet temperature and available space. Include the documents, sample or mounting drawing needed for approval.

MODEL-SPECIFIC ENQUIRY

Prepare your power-supply request.

Select models from the table, then enter quantities and application details. Copy the request into your message to CHSO.

Contact CHSO →

Preparing this list does not send a message.