CHSO / INDUSTRIAL POWER
HLW Adjustable CV/CC Power Supplies
High-power supplies with adjustable voltage and current control. Choose a 0–24 V, 0–36 V or 0–48 V output range, then specify the required voltage and current operating point.
6 series classes · 18 output versions
CASE SIZES / POWER CLASSES
HLW series at a glance
L × W × HSpecifications & drawing →
L × W × HSpecifications & drawing →
L × W × HSpecifications & drawing →
L × W × HSpecifications & drawing →
L × W × HSpecifications & drawing →
L × W × HSpecifications & drawing →
MODEL SELECTION
Match voltage and current.
18 output versions
Series class identifies the family. Use the exact voltage/current row for sizing. HLW voltage filters refer to maximum output voltage. Scroll the table horizontally on smaller screens.
| Model | Output (VDC) | Rated current (A) | Series class (W) | AC input | Case dimensions (mm) | Enquiry |
|---|---|---|---|---|---|---|
| HLW-1200-(0-24) | 0–24 | 50 | 1200 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1200-(0-36) | 0–36 | 33 | 1200 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1200-(0-48) | 0–48 | 25 | 1200 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1500-(0-24) | 0–24 | 62.5 | 1500 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1500-(0-36) | 0–36 | 42 | 1500 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1500-(0-48) | 0–48 | 31 | 1500 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1800-(0-24) | 0–24 | 75 | 1800 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1800-(0-36) | 0–36 | 50 | 1800 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-1800-(0-48) | 0–48 | 37.5 | 1800 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-2000-(0-24) | 0–24 | 80 | 2000 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-2000-(0-36) | 0–36 | 55 | 2000 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-2000-(0-48) | 0–48 | 42 | 2000 | 180–264 VAC | 291 × 132 × 68 mmL × W × H | |
| HLW-3000-(0-24) | 0–24 | 125 | 3000 | 180–264 VAC | 285 × 185 × 70 mmL × W × H | |
| HLW-3000-(0-36) | 0–36 | 83 | 3000 | 180–264 VAC | 285 × 185 × 70 mmL × W × H | |
| HLW-3000-(0-48) | 0–48 | 62.5 | 3000 | 180–264 VAC | 285 × 185 × 70 mmL × W × H | |
| HLW-4000-(0-24) | 0–24 | 167 | 4000 | 180–264 VAC | 315 × 208 × 73 mmL × W × H | |
| HLW-4000-(0-36) | 0–36 | 111 | 4000 | 180–264 VAC | 315 × 208 × 73 mmL × W × H | |
| HLW-4000-(0-48) | 0–48 | 83 | 4000 | 180–264 VAC | 315 × 208 × 73 mmL × W × H |
No matching output version. Reduce the current filter or choose another voltage.
INSTALLATION & LOAD CHECK
Check the complete operating condition.
Mains voltage and input selector
Continuous current and start-up demand
Cabinet temperature and airflow
Mounting holes, terminals and protective earth
Disconnect the supply before wiring or changing the input selector. Connect protective earth to the marked FG/PE terminal. Keep ventilation openings clear and use the selected model drawing for mounting. Capacitive, motor and pulsed loads require a start-up and transient-load check.
SELECTION SUPPORT
Questions before ordering
What must be confirmed for HLW constant-current operation?
Specify the required current-adjustment range, load type and voltage operating range. Confirm minimum stable output, CV/CC transition and any remote-control requirement for the selected model. A 0–48 V label alone does not define these functions.
How do I size a power supply for a load?
Match the DC voltage first. Add the continuous currents of the loads and account for start-up demand, operating duty and cabinet temperature. Check the exact output-version current; the series-class wattage alone is not a sizing value.
Can several output terminals supply separate voltages?
Repeated +V and −V terminals on a single-output supply belong to the same output. They do not create independent channels. Check the terminal drawing and permitted current per terminal.
Does an adjustable output retain the same power at every voltage?
The rated current remains a limit when voltage is reduced. When voltage is increased, current may need to be reduced to remain within the permitted output power. Confirm the operating point and derating curve.
What should I include in an enquiry?
Send the complete model, output voltage, continuous and start-up current, mains voltage, quantity, cabinet temperature and available space. Include the documents, sample or mounting drawing needed for approval.
MODEL-SPECIFIC ENQUIRY
Prepare your power-supply request.
Select models from the table, then enter quantities and application details. Copy the request into your message to CHSO.
Contact CHSO →Preparing this list does not send a message.