PRIVATE DESIGN PREVIEW Product data and supply terms are being verified. RFQ lists stay in this browser.
Wenzhou Changsong Electric Co., Ltd.
Catalogs & technical filesContact & inquiryEN
CHSOINDUSTRIAL ELECTRICALRequest a quote 0→
Products/Power Supplies

CHSO / INDUSTRIAL POWER

EDR DIN Rail Power Supplies

DIN rail AC/DC supplies with 12 V, 24 V and 48 V versions. Select by continuous current, enclosure temperature and the space available on the rail.

3 series classes · 9 output versions

EDR-120 AC/DC power supply
EDR DIN Rail Power Supplies

CASE SIZES / POWER CLASSES

EDR series at a glance

MODEL SELECTION

Match voltage and current.

Download selection table · CSV ↓

9 output versions

Series class identifies the family. Use the exact voltage/current row for sizing. HLW voltage filters refer to maximum output voltage. Scroll the table horizontally on smaller screens.

Output ratings and case dimensions
ModelOutput (VDC)Rated current (A)Series class (W)AC inputCase dimensions (mm)Enquiry
EDR-75-12126.37585–264 VAC32 × 125.2 × 102 mmW × H × D
EDR-75-24243.27585–264 VAC32 × 125.2 × 102 mmW × H × D
EDR-75-48481.67585–264 VAC32 × 125.2 × 102 mmW × H × D
EDR-120-12121012085–264 VAC40 × 125.2 × 113.5 mmW × H × D
EDR-120-2424512085–264 VAC40 × 125.2 × 113.5 mmW × H × D
EDR-120-48482.512085–264 VAC40 × 125.2 × 113.5 mmW × H × D
EDR-150-121212.515085–264 VAC40 × 125 × 113.5 mmW × H × D
EDR-150-24246.2515085–264 VAC40 × 125 × 113.5 mmW × H × D
EDR-150-48483.115085–264 VAC40 × 125 × 113.5 mmW × H × D

INSTALLATION & LOAD CHECK

Check the complete operating condition.

01

Mains voltage and input selector

02

Continuous current and start-up demand

03

Cabinet temperature and airflow

04

Mounting holes, terminals and protective earth

Disconnect the supply before wiring or changing the input selector. Connect protective earth to the marked FG/PE terminal. Keep ventilation openings clear and use the selected model drawing for mounting. Capacitive, motor and pulsed loads require a start-up and transient-load check.

SELECTION SUPPORT

Questions before ordering

How do I size a power supply for a load?

Match the DC voltage first. Add the continuous currents of the loads and account for start-up demand, operating duty and cabinet temperature. Check the exact output-version current; the series-class wattage alone is not a sizing value.

Can several output terminals supply separate voltages?

Repeated +V and −V terminals on a single-output supply belong to the same output. They do not create independent channels. Check the terminal drawing and permitted current per terminal.

Does an adjustable output retain the same power at every voltage?

The rated current remains a limit when voltage is reduced. When voltage is increased, current may need to be reduced to remain within the permitted output power. Confirm the operating point and derating curve.

What should I include in an enquiry?

Send the complete model, output voltage, continuous and start-up current, mains voltage, quantity, cabinet temperature and available space. Include the documents, sample or mounting drawing needed for approval.

MODEL-SPECIFIC ENQUIRY

Prepare your power-supply request.

Select models from the table, then enter quantities and application details. Copy the request into your message to CHSO.

Contact CHSO →

Preparing this list does not send a message.