LRS-450 Enclosed Power Supplies
LRS-450 single-output enclosed AC/DC power supplies. 12 V / 37.5 A, 24 V / 18.8 A, 36 V / 12.5 A, 48 V / 9.4 A. Case: 215 × 115 × 30 mm (L × W × H).
90–132 / 180–264 VAC; select with input switch · 4 output versions
MODEL SELECTION
Match voltage and current.
4 output versions
Series class identifies the family. Use the exact voltage/current row for sizing. HLW voltage filters refer to maximum output voltage. Scroll the table horizontally on smaller screens.
| Model | Output (VDC) | Rated current (A) | Series class (W) | AC input | Case dimensions (mm) | Enquiry |
|---|---|---|---|---|---|---|
| LRS-450-12 | 12 | 37.5 | 450 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-450-24 | 24 | 18.8 | 450 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-450-36 | 36 | 12.5 | 450 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H | |
| LRS-450-48 | 48 | 9.4 | 450 | 90–132 / 180–264 VAC; select with input switch | 215 × 115 × 30 mmL × W × H |
No matching output version. Reduce the current filter or choose another voltage.
ELECTRICAL DATA
LRS-450 specifications
| Model | Ripple & noise (mVp-p, max.) | Efficiency | Line regulation | Load regulation | Voltage adjustment |
|---|---|---|---|---|---|
| LRS-450-12 | 150 | 87% | ±0.5% | ±1% | ±10% |
| LRS-450-24 | 200 | 88% | ±0.5% | ±0.5% | ±10% |
| LRS-450-36 | 200 | 90% | ±0.5% | ±0.5% | ±10% |
| LRS-450-48 | 200 | 91% | ±0.5% | ±0.5% | ±10% |
Efficiency is the listed model value; operating conditions affect actual efficiency. Ripple/noise comparison requires the same measurement bandwidth and probe method.
| Parameter | Specification |
|---|---|
| AC input | 90–132 / 180–264 VAC; select with input switch |
| DC input | 240–370 VDC; switch at 230 VAC |
| Operating ambient | −10 to +60 °C |
| Humidity | 20–90% RH; non-condensing installation |
| Overload protection | 110–150%; hiccup protection, automatic recovery after fault removal |
| Overvoltage protection | Output shutdown; confirm reset sequence for the selected version |
| Mounting | Chassis mounting; use the matched mounting-hole drawing |
| Overall dimensions | 215 × 115 × 30 mm (L × W × H) |
MECHANICAL FIT
Dimensions and terminal layout
215 × 115 × 30 mm (L × W × H). Allow additional room for wiring and airflow.
Read terminal markings on the selected unit. L/N are AC input; FG/PE is protective earth; +V/−V are DC output. Terminal numbering and the number of parallel terminals vary by model.
Selection notes
- The series class is a model-family designation. Select using the voltage and current of the exact output version; do not divide the series-class wattage by the voltage to infer current.
- Check load start-up current, cabinet temperature and ventilation before sizing the supply. Request a derating curve where operation approaches the temperature limit.
- Set the AC input selector for the actual mains voltage before energising the unit.
- Confirm protection reset behaviour and the applicable compliance documents with the order. Ratings shown here do not establish a certification approval.
INSTALLATION & LOAD CHECK
Check the complete operating condition.
Mains voltage and input selector
Continuous current and start-up demand
Cabinet temperature and airflow
Mounting holes, terminals and protective earth
Disconnect the supply before wiring or changing the input selector. Connect protective earth to the marked FG/PE terminal. Keep ventilation openings clear and use the selected model drawing for mounting. Capacitive, motor and pulsed loads require a start-up and transient-load check.
SELECTION SUPPORT
Questions before ordering
How do I size a power supply for a load?
Match the DC voltage first. Add the continuous currents of the loads and account for start-up demand, operating duty and cabinet temperature. Check the exact output-version current; the series-class wattage alone is not a sizing value.
Can several output terminals supply separate voltages?
Repeated +V and −V terminals on a single-output supply belong to the same output. They do not create independent channels. Check the terminal drawing and permitted current per terminal.
Does an adjustable output retain the same power at every voltage?
The rated current remains a limit when voltage is reduced. When voltage is increased, current may need to be reduced to remain within the permitted output power. Confirm the operating point and derating curve.
What should I include in an enquiry?
Send the complete model, output voltage, continuous and start-up current, mains voltage, quantity, cabinet temperature and available space. Include the documents, sample or mounting drawing needed for approval.
MODEL-SPECIFIC ENQUIRY
Prepare your power-supply request.
Select models from the table, then enter quantities and application details. Copy the request into your message to CHSO.
Contact CHSO →Preparing this list does not send a message.