CHSO / CABLE MANAGEMENT
Standard Nylon Cable Glands
PA6 cable entries for control panels, junction boxes and general electrical enclosures. Compare Metric, PG, NPT and G threads within one standard range.
PA6 body · NBR seal

01 / SELECTION LOGIC
Define the installation.
The thread size alone does not identify the correct sealing configuration.
Cable outside diameter and tolerance
Thread standard, size and panel thickness
Environment, sealing arrangement and required documents
Quantity by size, colour and accessory configuration
02 / DIMENSIONAL REFERENCE
Find your configuration.
80 configurations
Select by the complete row. Repeated nominal sizes can have different cable ranges or dimensions. Scroll tables horizontally on smaller screens.
Metric M12–M63
| Model No. | Thread Size (Metric) | Mounting Hole Diameter(mm) | Thread Length (mm) | Thread O.D. (mm) | Reference Panel Thickness (mm; confirm drawing) | Cable Range (mm) | Wrench Size (mm) | Standard Packaging (pcs/bag) |
|---|---|---|---|---|---|---|---|---|
| SC-M12 | M12×1.5 | Φ12.2-12.5 | 9 | 12 | 3 | 3-6.5 | 18/16 | 100 |
| SC-M12 | M12×1.5 | Φ12.2-12.5 | 9 | 12 | 3 | 2-5 | 18/16 | 100 |
| SC-M16 | M16×1.5 | Φ16.2-16.5 | 9 | 16 | 3 | 4-8 | 22/19 | 100 |
| SC-M16 | M16×1.5 | Φ16.2–16.5 | 9 | 16 | 3 | 2-6 | 22/19 | 100 |
| SC-M18 | M18×1.5 | Φ18.2-18.5 | 9 | 18 | 3 | 5-10 | 24/22 | 100 |
| SC-M18 | M18×1.5 | Φ18.2-18.5 | 9 | 18 | 3 | 3-7 | 24/22 | 100 |
| SC-M20 | M20×1.5 | Φ20.2-20.5 | 9 | 20 | 5 | 6-12 | 27/24 | 100 |
| SC-M20 | M20×1.5 | Φ20.2-20.5 | 9 | 20 | 4 | 5-9 | 27/24 | 100 |
| SC-M22 | M22×1.5 | Φ22.2-22.5 | 10 | 22 | 5 | 10-14 | 30/27 | 100 |
| SC-M22 | M22×1.5 | Φ22.2-22.5 | 10 | 22 | 5 | 6-12 | 30/27 | 100 |
| SC-M24 | M24×1.5 | Φ24.2-24.5 | 10 | 24 | 5 | 12-15 | 33/28 | 100 |
| SC-M24 | M24×1.5 | Φ24.2-24.5 | 10 | 24 | 5 | 10-12 | 33/28 | 100 |
| SC-M25 | M25×1.5 | Φ25.2-25.5 | 10 | 25 | 5 | 13-15 | 33/28 | 100 |
| SC-M25 | M25×1.5 | Φ25.2-25.5 | 10 | 25 | 5 | 8-12 | 33/28 | 100 |
| SC-M25 | M25×1.5 | Φ25.2-25.5 | 12 | 25 | 5 | 13-18 | 33/30 | 100 |
| SC-M25 | M25×1.5 | Φ25.2-25.5 | 12 | 25 | 5 | 9-16 | 33/33 | 100 |
| SC-M27 | M27×1.5 | Φ27.2-27.5 | 12 | 27 | 5 | 13-18 | 35/33 | 100 |
| SC-M27 | M27×1.5 | Φ27.2-27.5 | 12 | 27 | 6 | 9-16 | 35/33 | 100 |
| SC-M30 | M30×1.5 | Φ30.2-30.5 | 12 | 30 | 6 | 16-22 | 37/37 | 100 |
| SC-M30 | M30×1.5 | Φ30.2-30.5 | 12 | 30 | 6 | 16-20 | 37/37 | 100 |
| SC-M32 | M32×1.5 | Φ32.2-32.5 | 12 | 32 | 6 | 16-21 | 39/35 | 100 |
| SC-M32 | M32×1.5 | Φ32.2-32.5 | 12 | 32 | 6 | 13-18 | 39/35 | 100 |
| SC-M36 | M36×1.5 | Φ36.2-37 | 12 | 36 | 6 | 18-25 | 45/42 | 50 |
| SC-M36 | M36×1.5 | Φ36.2-37 | 12 | 36 | 7 | 13-20 | 45/42 | 50 |
| SC-M40 | M40×1.5 | Φ40.2-41 | 17 | 40 | 7 | 20-26 | 52/52 | 50 |
| SC-M40 | M40×1.5 | Φ40.2-41 | 17 | 40 | 7 | 22-32 | 52/52 | 50 |
| SC-M50 | M50×1.5 | Φ50.5-51 | 19 | 50 | 10 | 32-38 | 60/60 | 20 |
| SC-M50 | M50×1.5 | Φ50.5-51 | 19 | 50 | 10 | 25-36 | 60/60 | 20 |
| SC-M63 | M63×1.5 | Φ63.5-64 | 19 | 63 | 10 | 37-44 | 74/69 | 10 |
| SC-M63 | M63×1.5 | Φ63.5-64 | 19 | 63 | 10 | 29-35 | 74/69 | 10 |
Metric M72–M114
| Thread Size | Cable Range (mm) | Thread Length (mm) | Thread O.D. (mm) | Wrench Size (mm) |
|---|---|---|---|---|
| M72×2 | 40–55 | 26 | 72 | 85/85 |
| M75×2 | 40–55 | 25.3 | 75 | 87/79 |
| M80×2 | 55–66 | 22.2 | 80 | 93/98 |
| M88×2 | 55–66 | 22.2 | 88 | 97/97 |
| M90×2 | 66–77 | 25 | 90 | 110/120 |
| M100×2 | 80–90 | 27.7 | 100 | 110/119 |
| M114×2 | 80–90 | 28 | 114 | 115/126 |
PG7–PG63
| Model No. | Thread Size (PG) | Mounting Hole Diameter (mm) | Thread Length (mm) | Thread O.D. (mm) | Reference panel thickness (mm; confirm drawing) | Cable Range (mm) | Wrench Size (mm) | Standard Packaging (pcs/bag) |
|---|---|---|---|---|---|---|---|---|
| SC-PG7 | PG7 | Φ12.6-13 | 9 | 12.5 | 3 | 3-6.5 | 18/16 | 100 |
| SC-PG7 | PG7 | Φ12.6-13 | 9 | 12.5 | 3 | 2-5 | 18/16 | 100 |
| SC-PG9 | PG9 | Φ15.3-15.5 | 9 | 15.2 | 3 | 4-8 | 22/19 | 100 |
| SC-PG9 | PG9 | Φ15.3-15.5 | 9 | 15.2 | 3 | 2-6 | 22/19 | 100 |
| SC-PG11 | PG11 | Φ18.7-19 | 9 | 18.6 | 3 | 5-10 | 24/22 | 100 |
| SC-PG11 | PG11 | Φ18.7-19 | 9 | 18.6 | 3 | 3-7 | 24/22 | 100 |
| SC-PG13.5 | PG13.5 | Φ20.5-21 | 9 | 20.4 | 4 | 6-12 | 27/24 | 100 |
| SC-PG13.5 | PG13.5 | Φ20.5-21 | 9 | 20.4 | 4 | 5-9 | 27/24 | 100 |
| SC-PG16 | PG16 | Φ22.6-23 | 10 | 22.5 | 5 | 10-14 | 30/27 | 100 |
| SC-PG16 | PG16 | Φ22.6-23 | 10 | 22.5 | 5 | 6-12 | 30/27 | 100 |
| SC-PG19 | PG19 | Φ24.2-24.5 | 10 | 24 | 5 | 12-15 | 30/28 | 100 |
| SC-PG19 | PG19 | Φ24.2-24.5 | 10 | 24 | 5 | 8-12 | 30/28 | 100 |
| SC-PG21 | PG21 | Φ28.5-29 | 12 | 28.3 | 5 | 13-18 | 36/33 | 100 |
| SC-PG21 | PG21 | Φ28.5-29 | 12 | 28.3 | 5 | 9-16 | 36/33 | 100 |
| SC-PG25 | PG25 | Φ30.2-30.5 | 12 | 30 | 6 | 15-22 | 37/35 | 100 |
| SC-PG25 | PG25 | Φ30.2-30.5 | 12 | 30 | 6 | 16-20 | 37/35 | 100 |
| SC-PG29 | PG29 | Φ37.2-37.5 | 12 | 37 | 6 | 18-25 | 45/42 | 50 |
| SC-PG29 | PG29 | Φ37.2-37.5 | 12 | 37 | 6 | 13-20 | 45/42 | 50 |
| SC-PG36 | PG36 | Φ47.3-48 | 17 | 47 | 7 | 22-32 | 58/52 | 20 |
| SC-PG36 | PG36 | Φ47.3-48 | 17 | 47 | 7 | 20-26 | 58/52 | 20 |
| SC-PG42 | PG42 | Φ54.5-55 | 19 | 54 | 7 | 32-38 | 65/60 | 20 |
| SC-PG42 | PG42 | Φ54.5-55 | 19 | 54 | 7 | 25-31 | 65/60 | 20 |
| SC-PG48 | PG48 | Φ60-61 | 19 | 59.3 | 7 | 37-44 | 70/69 | 10 |
| SC-PG48 | PG48 | Φ60-61 | 19 | 59.3 | 7 | 25-36 | 70/69 | 10 |
| SC-PG63 | PG63 | Φ71.5-72 | 27 | 71 | 19 | 42-52 | 83/75 | 10 |
| SC-PG63 | PG63 | Φ71.5-72 | 27 | 71 | 19 | 32-40 | 83/75 | 10 |
NPT threads
| NPT size (in.) | Cable range (mm) | Thread OD C1 (mm) | Thread length C2 (mm) | Wrench size (mm) | Cap nut height (mm) | Cap nut OD (mm) | Overall height (mm) |
|---|---|---|---|---|---|---|---|
| 1/4 | 3–6.5 | 13.2 | 9 | 18 | 14.2 | 15.2 | 28.5 |
| 3/8 | 6–10 | 17.1 | 15 | 22 | 16.1 | 21.4 | 38.7 |
| 1/2 | 6–12 | 21.3 | 13 | 27 | 16.4 | 23.4 | 39.4 |
| 1/2 | 8–14 | 21.3 | 15 | 27 | 15.9 | 23.6 | 39.3 |
| 3/4 | 12–18 | 26.6 | 15.5 | 33 | 22.5 | 32.6 | 49.8 |
| 1 | 18–25 | 33.5 | 17 | 41 | 22.8 | 41.6 | 52.5 |
| 1 1/4 | 24–32 | 42 | 17 | 50 | 29.3 | 51.7 | 61.8 |
| 1 1/2 | 22–32 | 48 | 17 | 57 | 29.8 | 51.8 | 61.1 |
| 2 | 37–44 | 59.2 | 18.5 | 73 | 32.3 | 64.2 | 67.1 |
G / BSPP threads
| Thread | Cable Range (mm) | Thread OD (C1), mm | Thread Length (C2), mm | Wrench Size (mm) |
|---|---|---|---|---|
| G 1/4 | 3–6.5 | 13 | 8 | 16 |
| G 3/8 | 5–10 | 16.5 | 9 | 22 |
| G 1/2 | 6–12 | 20.9 | 9 | 24 |
| G 3/4 | 13–18 | 26.4 | 11 | 33 |
| G 1 | 18–25 | 33 | 12 | 42 |
| G 1 1/4 | 25–32 | 41.9 | 15 | 52 |
| G 1 1/2 | 32–38 | 47.5 | 15 | 60 |
| G 2 | 37–44 | 59.6 | 15 | 68 |
No matching configuration. Try another size or reset the filters.
TECHNICAL SELECTION
Specify the thread precisely.
Thread designation, cable clamping range and panel opening are different dimensions.
| Thread family | How to specify it | Independent selection check |
|---|---|---|
| Metric | Diameter × pitch, e.g. M20 × 1.5 | Match both dimensions; cable range is selected separately. |
| PG | Full PG size, e.g. PG13.5 | PG is a different thread system; do not replace it using nominal size alone. |
| NPT | Nominal inch size plus NPT | Tapered thread. Follow the specified engagement and sealing method. |
| G / BSPP | Nominal inch size plus G | Parallel thread. Use the specified interface seal; G is not NPT. |
The CHSO standard-nylon tables list M12–M63 at 1.5 mm pitch and the listed M72–M114 sizes at 2 mm pitch. Use the selected configuration; these pitches are not a rule for every manufacturer or gland series.
TECHNICAL NOTES
Confirm before ordering.
- Standard nylon is supplied without a flat sealing washer by default: IP55. IP68 requires the specified flat washer, the correct seal configuration and correct installation.
- Cable range refers to the outside diameter of the cable jacket, not conductor cross-section. A thread size can have more than one sealing range.
- Panel-thickness values are catalogue references. Confirm usable thread engagement with the selected washer, locknut and enclosure.
- Metric and PG references use the original SC product codes. Large Metric, NPT and G entries are selected by thread and cable range.
SELECTION SUPPORT
Common questions.
Does M20 identify the cable diameter?
No. M20 identifies the mounting thread diameter. The cable outside diameter must fit the sealing range in the selected table row; a single thread size can have different inserts.
What is supplied for standard nylon sealing?
The standard configuration has a PA6 body and NBR seal and is supplied without a flat washer by default, with IP55 protection. IP68 requires the specified flat washer, suitable cable fit and correct installation.
How should I specify an extended thread?
Give the panel thickness, washer and locknut arrangement and the required usable thread engagement. Confirm the drawing before ordering; nominal thread size does not give the thread length.
SOURCING / QUOTATION
Send a clear specification.
Include the series or reference, quantities and installation requirements. Add the drawing, sample or documentation you need for approval.
Contact CHSO →Your enquiry checklist
- Cable outside diameter and tolerance
- Thread standard, size and panel thickness
- Environment, sealing arrangement and required documents
- Quantity by size, colour and accessory configuration