Standard Nylon Cable Glands

PA6 cable entries for control panels, junction boxes and general electrical enclosures. Compare Metric, PG, NPT and G threads within one standard range.

PA6 body · NBR seal

CHSO Standard Nylon Cable Glands
General cable entry

01 / SELECTION LOGIC

Define the installation.

The thread size alone does not identify the correct sealing configuration.

01

Cable outside diameter and tolerance

02

Thread standard, size and panel thickness

03

Environment, sealing arrangement and required documents

04

Quantity by size, colour and accessory configuration

02 / DIMENSIONAL REFERENCE

Find your configuration.

Download dimensions · CSV ↓

80 configurations

Select by the complete row. Repeated nominal sizes can have different cable ranges or dimensions. Scroll tables horizontally on smaller screens.

Metric M12–M63

Metric M12–M63 — catalogue dimensions
Model No.Thread Size (Metric)Mounting Hole Diameter(mm)Thread Length (mm)Thread O.D. (mm)Reference Panel Thickness (mm; confirm drawing)Cable Range (mm)Wrench Size (mm)Standard Packaging (pcs/bag)
SC-M12M12×1.5Φ12.2-12.591233-6.518/16100
SC-M12M12×1.5Φ12.2-12.591232-518/16100
SC-M16M16×1.5Φ16.2-16.591634-822/19100
SC-M16M16×1.5Φ16.2–16.591632-622/19100
SC-M18M18×1.5Φ18.2-18.591835-1024/22100
SC-M18M18×1.5Φ18.2-18.591833-724/22100
SC-M20M20×1.5Φ20.2-20.592056-1227/24100
SC-M20M20×1.5Φ20.2-20.592045-927/24100
SC-M22M22×1.5Φ22.2-22.51022510-1430/27100
SC-M22M22×1.5Φ22.2-22.5102256-1230/27100
SC-M24M24×1.5Φ24.2-24.51024512-1533/28100
SC-M24M24×1.5Φ24.2-24.51024510-1233/28100
SC-M25M25×1.5Φ25.2-25.51025513-1533/28100
SC-M25M25×1.5Φ25.2-25.5102558-1233/28100
SC-M25M25×1.5Φ25.2-25.51225513-1833/30100
SC-M25M25×1.5Φ25.2-25.5122559-1633/33100
SC-M27M27×1.5Φ27.2-27.51227513-1835/33100
SC-M27M27×1.5Φ27.2-27.5122769-1635/33100
SC-M30M30×1.5Φ30.2-30.51230616-2237/37100
SC-M30M30×1.5Φ30.2-30.51230616-2037/37100
SC-M32M32×1.5Φ32.2-32.51232616-2139/35100
SC-M32M32×1.5Φ32.2-32.51232613-1839/35100
SC-M36M36×1.5Φ36.2-371236618-2545/4250
SC-M36M36×1.5Φ36.2-371236713-2045/4250
SC-M40M40×1.5Φ40.2-411740720-2652/5250
SC-M40M40×1.5Φ40.2-411740722-3252/5250
SC-M50M50×1.5Φ50.5-5119501032-3860/6020
SC-M50M50×1.5Φ50.5-5119501025-3660/6020
SC-M63M63×1.5Φ63.5-6419631037-4474/6910
SC-M63M63×1.5Φ63.5-6419631029-3574/6910

Metric M72–M114

Metric M72–M114 — catalogue dimensions
Thread SizeCable Range (mm)Thread Length (mm)Thread O.D. (mm)Wrench Size (mm)
M72×240–55267285/85
M75×240–5525.37587/79
M80×255–6622.28093/98
M88×255–6622.28897/97
M90×266–772590110/120
M100×280–9027.7100110/119
M114×280–9028114115/126

PG7–PG63

PG7–PG63 — catalogue dimensions
Model No.Thread Size (PG)Mounting Hole Diameter (mm)Thread Length (mm)Thread O.D. (mm)Reference panel thickness (mm; confirm drawing)Cable Range (mm)Wrench Size (mm)Standard Packaging (pcs/bag)
SC-PG7PG7Φ12.6-13912.533-6.518/16100
SC-PG7PG7Φ12.6-13912.532-518/16100
SC-PG9PG9Φ15.3-15.5915.234-822/19100
SC-PG9PG9Φ15.3-15.5915.232-622/19100
SC-PG11PG11Φ18.7-19918.635-1024/22100
SC-PG11PG11Φ18.7-19918.633-724/22100
SC-PG13.5PG13.5Φ20.5-21920.446-1227/24100
SC-PG13.5PG13.5Φ20.5-21920.445-927/24100
SC-PG16PG16Φ22.6-231022.5510-1430/27100
SC-PG16PG16Φ22.6-231022.556-1230/27100
SC-PG19PG19Φ24.2-24.51024512-1530/28100
SC-PG19PG19Φ24.2-24.5102458-1230/28100
SC-PG21PG21Φ28.5-291228.3513-1836/33100
SC-PG21PG21Φ28.5-291228.359-1636/33100
SC-PG25PG25Φ30.2-30.51230615-2237/35100
SC-PG25PG25Φ30.2-30.51230616-2037/35100
SC-PG29PG29Φ37.2-37.51237618-2545/4250
SC-PG29PG29Φ37.2-37.51237613-2045/4250
SC-PG36PG36Φ47.3-481747722-3258/5220
SC-PG36PG36Φ47.3-481747720-2658/5220
SC-PG42PG42Φ54.5-551954732-3865/6020
SC-PG42PG42Φ54.5-551954725-3165/6020
SC-PG48PG48Φ60-611959.3737-4470/6910
SC-PG48PG48Φ60-611959.3725-3670/6910
SC-PG63PG63Φ71.5-7227711942-5283/7510
SC-PG63PG63Φ71.5-7227711932-4083/7510

NPT threads

NPT threads — catalogue dimensions
NPT size (in.)Cable range (mm)Thread OD C1 (mm)Thread length C2 (mm)Wrench size (mm)Cap nut height (mm)Cap nut OD (mm)Overall height (mm)
1/43–6.513.291814.215.228.5
3/86–1017.1152216.121.438.7
1/26–1221.3132716.423.439.4
1/28–1421.3152715.923.639.3
3/412–1826.615.53322.532.649.8
118–2533.5174122.841.652.5
1 1/424–3242175029.351.761.8
1 1/222–3248175729.851.861.1
237–4459.218.57332.364.267.1

G / BSPP threads

G / BSPP threads — catalogue dimensions
ThreadCable Range (mm)Thread OD (C1), mmThread Length (C2), mmWrench Size (mm)
G 1/43–6.513816
G 3/85–1016.5922
G 1/26–1220.9924
G 3/413–1826.41133
G 118–25331242
G 1 1/425–3241.91552
G 1 1/232–3847.51560
G 237–4459.61568

TECHNICAL SELECTION

Specify the thread precisely.

Thread designation, cable clamping range and panel opening are different dimensions.

Mounting-thread selection guide
Thread familyHow to specify itIndependent selection check
MetricDiameter × pitch, e.g. M20 × 1.5Match both dimensions; cable range is selected separately.
PGFull PG size, e.g. PG13.5PG is a different thread system; do not replace it using nominal size alone.
NPTNominal inch size plus NPTTapered thread. Follow the specified engagement and sealing method.
G / BSPPNominal inch size plus GParallel thread. Use the specified interface seal; G is not NPT.

The CHSO standard-nylon tables list M12–M63 at 1.5 mm pitch and the listed M72–M114 sizes at 2 mm pitch. Use the selected configuration; these pitches are not a rule for every manufacturer or gland series.

TECHNICAL NOTES

Confirm before ordering.

SELECTION SUPPORT

Common questions.

Does M20 identify the cable diameter?

No. M20 identifies the mounting thread diameter. The cable outside diameter must fit the sealing range in the selected table row; a single thread size can have different inserts.

What is supplied for standard nylon sealing?

The standard configuration has a PA6 body and NBR seal and is supplied without a flat washer by default, with IP55 protection. IP68 requires the specified flat washer, suitable cable fit and correct installation.

How should I specify an extended thread?

Give the panel thickness, washer and locknut arrangement and the required usable thread engagement. Confirm the drawing before ordering; nominal thread size does not give the thread length.

SOURCING / QUOTATION

Send a clear specification.

Include the series or reference, quantities and installation requirements. Add the drawing, sample or documentation you need for approval.

Contact CHSO →

Your enquiry checklist

  • Cable outside diameter and tolerance
  • Thread standard, size and panel thickness
  • Environment, sealing arrangement and required documents
  • Quantity by size, colour and accessory configuration