Metal cable glands with a shield contact for screened cables. Select against both the outer cable jacket and the exposed shield diameter.

Metal body with shield contact

CHSO EMC Cable Glands
Screened cable entry

01 / SELECTION LOGIC

Define the installation.

The thread size alone does not identify the correct sealing configuration.

01

Cable jacket outside diameter and exposed shield diameter

02

Shield type, preparation length and required contact arrangement

03

Conductive enclosure interface, thread and panel thickness

04

Quantity, approved drawing and required EMC evidence

02 / DIMENSIONAL REFERENCE

Find your configuration.

Download dimensions · CSV ↓

11 configurations

Select by the complete row. Repeated nominal sizes can have different cable ranges or dimensions. Scroll tables horizontally on smaller screens.

Metric configurations

Metric configurations — catalogue dimensions
Metric ThreadCable Range (mm)Thread OD (mm)Thread Length (mm)Wrench Size (mm)Shield Contact Range (mm)
M8×12-58512Request model drawing
M10×13-6.510714Request model drawing
M12×1.53-6.512714Request model drawing
M14×1.54-814717Request model drawing
M16×1.54-816818Request model drawing
M18×1.55-1018820Request model drawing
M20×1.56-1220822Request model drawing
M24×1.510-1424924/27Request model drawing
M28×1.513-1828930Request model drawing
M32×1.515-22321035Request model drawing
M100×270-8010015110Request model drawing

TECHNICAL NOTES

Confirm before ordering.

SELECTION SUPPORT

Common questions.

Is cable range the same as shield-contact range?

No. Cable range concerns the outer jacket. The contact must also fit the exposed screen, so its contact range needs the selected model drawing.

Does an EMC gland alone establish system shielding performance?

No. Shield preparation, contact geometry, enclosure bonding and the complete installation affect performance.

What cable information is needed?

Provide jacket diameter, exposed shield diameter, shield construction, preparation length and the mounting-interface drawing.

SOURCING / QUOTATION

Send a clear specification.

Include the series or reference, quantities and installation requirements. Add the drawing, sample or documentation you need for approval.

Contact CHSO →

Your enquiry checklist

  • Cable jacket outside diameter and exposed shield diameter
  • Shield type, preparation length and required contact arrangement
  • Conductive enclosure interface, thread and panel thickness
  • Quantity, approved drawing and required EMC evidence