EMC Cable Glands
Metal cable glands with a shield contact for screened cables. Select against both the outer cable jacket and the exposed shield diameter.
Metal body with shield contact

01 / SELECTION LOGIC
Define the installation.
The thread size alone does not identify the correct sealing configuration.
Cable jacket outside diameter and exposed shield diameter
Shield type, preparation length and required contact arrangement
Conductive enclosure interface, thread and panel thickness
Quantity, approved drawing and required EMC evidence
02 / DIMENSIONAL REFERENCE
Find your configuration.
11 configurations
Select by the complete row. Repeated nominal sizes can have different cable ranges or dimensions. Scroll tables horizontally on smaller screens.
Metric configurations
| Metric Thread | Cable Range (mm) | Thread OD (mm) | Thread Length (mm) | Wrench Size (mm) | Shield Contact Range (mm) |
|---|---|---|---|---|---|
| M8×1 | 2-5 | 8 | 5 | 12 | Request model drawing |
| M10×1 | 3-6.5 | 10 | 7 | 14 | Request model drawing |
| M12×1.5 | 3-6.5 | 12 | 7 | 14 | Request model drawing |
| M14×1.5 | 4-8 | 14 | 7 | 17 | Request model drawing |
| M16×1.5 | 4-8 | 16 | 8 | 18 | Request model drawing |
| M18×1.5 | 5-10 | 18 | 8 | 20 | Request model drawing |
| M20×1.5 | 6-12 | 20 | 8 | 22 | Request model drawing |
| M24×1.5 | 10-14 | 24 | 9 | 24/27 | Request model drawing |
| M28×1.5 | 13-18 | 28 | 9 | 30 | Request model drawing |
| M32×1.5 | 15-22 | 32 | 10 | 35 | Request model drawing |
| M100×2 | 70-80 | 100 | 15 | 110 | Request model drawing |
No matching configuration. Try another size or reset the filters.
TECHNICAL NOTES
Confirm before ordering.
- The jacket clamping range is not the shield-contact range. Request the selected model drawing before final selection.
- A conductive contact path depends on cable preparation, gland assembly and enclosure bonding. No shielding-effectiveness value is claimed for the complete installation.
- Confirm body material, seal material and ingress-protection configuration for the selected model.
SELECTION SUPPORT
Common questions.
Is cable range the same as shield-contact range?
No. Cable range concerns the outer jacket. The contact must also fit the exposed screen, so its contact range needs the selected model drawing.
Does an EMC gland alone establish system shielding performance?
No. Shield preparation, contact geometry, enclosure bonding and the complete installation affect performance.
What cable information is needed?
Provide jacket diameter, exposed shield diameter, shield construction, preparation length and the mounting-interface drawing.
SOURCING / QUOTATION
Send a clear specification.
Include the series or reference, quantities and installation requirements. Add the drawing, sample or documentation you need for approval.
Contact CHSO →Your enquiry checklist
- Cable jacket outside diameter and exposed shield diameter
- Shield type, preparation length and required contact arrangement
- Conductive enclosure interface, thread and panel thickness
- Quantity, approved drawing and required EMC evidence