Copper connectors

CCT C-Type Copper Compression Clamps

C-shaped copper compression clamps for copper-wire splicing. Model selection uses the specified conductor-section band and the clamp geometry.

7.5–700 mm² selection bandsCopperCompression connection
CCT C-Type Copper Compression Clamps
CCT · Copper connectors
Technical data

Material, connection & construction

CCT product specifications
ParameterSpecification
SeriesCCT
Product formC-Type Copper Compression Clamps
Conductor / interfaceCopper-wire splice / tap connection
Body materialCopper
Size range7.5–700 mm² selection bands
Connection methodCompression joint
InsulationNon-insulated; provide application-specific joint insulation and enclosure protection
DimensionsMillimetres; conductor cross-section in mm²
Model selection

Models & dimensions

All dimensional values are in millimetres. Conductor sizes are in mm². Use the symbols in the drawing for the selected construction.

Select a compatible C-crimp die and conductor arrangement. The range column describes the connection selection band, not a mounting-hole size.

CCT C-Type Copper Compression Clamps construction
Product construction
CCT C-Type Copper Compression Clamps dimension symbols
Dimensional geometry · All dimensions in mm
Use the dimension symbols in this series drawing; symbols can differ between constructions.

CCT model dimensions
ModelConductor section mm²H1H2WLTC
CCT-107.5–119.56.36.2121.64
CCT-1611.5–1611.87.87.31325
CCT-2014–2012.88.69.7132.94
CCT-2621–2614.710.210.9163.26.5
CCT-4427–441912.414.42048.5
CCT-6045–602115.415.12249.7
CCT-7661–7624.417.317.622510.8
CCT-9877–9827.820.818.825512.8
CCT-12299–12229.822.121.2265.513.5
CCT-154123–1543425.724.428617
CCT-190155–1903728.525.435617.4
CCT-240191–2404030.228.540719
CCT-288241–28844.534.731.145722.3
CCT-365289–36547.537.73450725
CCT-450366–4505742.541601028
CCT-560451–560624645651121
CCT-700561–700685249.5701234
Application & installation

Select the complete connection

Application fit

  • Copper conductor tapping and splicing
  • Equipotential bonding and earthing conductors with a specified C-crimp system
  • Permanent copper connections where the conductor combination fits the selected clamp

Ordering checklist

Specify CCT construction, conductor material and nominal section, conductor strand class, both conductor sizes, joint space, tool/die system, quantity and required finish.

Installation sequence

  1. Isolate the circuit and verify that it is de-energised. Identify the conductor material, section and strand construction.
  2. Select the matching connector, tool and die combination. Strip to the required insertion length without cutting or losing strands.
  3. Insert the conductor fully and crimp in the sequence and number of compressions specified for the connector/tool system. Do not substitute a die solely because its size marking looks similar.
  4. Inspect the compression, conductor retention and contact alignment. Restore suitable insulation and protection, then carry out the assembly checks before energising.
Practical answers

Frequently asked questions

What distinguishes CCT from other cable connectors?

C-shaped copper compression clamps for copper-wire splicing. Model selection uses the specified conductor-section band and the clamp geometry.

How do I select the correct CCT size?

Specify CCT construction, conductor material and nominal section, conductor strand class, both conductor sizes, joint space, tool/die system, quantity and required finish.

What should I check before ordering this series?

Select a compatible C-crimp die and conductor arrangement. The range column describes the connection selection band, not a mounting-hole size.

Does the conductor size determine a universal current rating?

No. Connection current depends on the cable material and size, insulation temperature, terminal interface, installation conditions and verified crimp system. Select the whole circuit and connection together.

Can I use any crimping die with the same size number?

No. Die profile, tool force, connector wall thickness and conductor construction work as a system. Use the specified tool/die combination for the chosen connector.

Does this connector provide electrical insulation?

No. These are conductive connection components. Provide the joint insulation, sealing and mechanical protection required by the cable system and installation.

Distributor & panel-builder inquiries

Specify the conductor.
Match the connection.

Include CCT model and construction, conductor material and size, stud-hole or joint requirements, quantities and packaging needs.

Request pricing ↗