Copper lugs

AUS Copper Cable Lugs

Tinned copper tube lugs in the AUS dimensional series. The 6–1000 mm² range includes alternative stud-hole sizes and a defined overall-length schedule.

6–1000 mm²T2 copperBolted palm
AUS Copper Cable Lugs
AUS · Copper lugs
Technical data

Material, connection & construction

AUS product specifications
ParameterSpecification
SeriesAUS
Product formCopper Cable Lugs
Conductor / interfaceCopper conductor to bolted equipment terminal
Body materialT2 copper
Size range6–1000 mm²
Connection methodCrimped barrel with bolted palm
InsulationNon-insulated; provide application-specific joint insulation and enclosure protection
DimensionsMillimetres; conductor cross-section in mm²
FinishTin-plated copper
Copper purity≥99.9% T2 copper
Lug / sleeve material temperature range−55°C to +150°C; the cable insulation and complete connection may impose a lower limit
Model selection

Models & dimensions

All dimensional values are in millimetres. Conductor sizes are in mm². Use the symbols in the drawing for the selected construction.

AUS and SC dimensions differ. Match the barrel and palm geometry as well as the cable cross-section.

AUS Copper Cable Lugs construction
Product construction
AUS Copper Cable Lugs dimension symbols
Dimensional geometry · All dimensions in mm
Use the dimension symbols in this series drawing; symbols can differ between constructions.

AUS model dimensions
ModelStud hole ØBarrel OD DBarrel ID dOverall length L
AUS-65.2/6.2/8.25.53.831.5
AUS-106.2/8.264.534.5
AUS-166.2/8.2/10.58.55.543.5
AUS-256.2/8.2/10.510748
AUS-356.2/8.2/10.5/12.512.58.252
AUS-508.2/10.5/12.514.51064
AUS-708.2/10.5/12.516.511.568
AUS-9510.5/12.51913.578
AUS-12012.5/16.52115.586
AUS-15012.5/16.523.51794
AUS-18516.525.519101
AUS-24016.52921.5111
AUS-30016.5/20.53224.5119
AUS-40016.5/20.538.527.5140
AUS-50016.5/20.54231150
AUS-63020.54434.5160
AUS-80022.55240195
AUS-100022.55844195
Application & installation

Select the complete connection

Application fit

  • Cable ends in power-distribution and control cabinets
  • Bolted connections to compatible copper busbars and equipment terminals
  • Replacement terminations where barrel, hole and palm dimensions match

Ordering checklist

Specify AUS construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

Installation sequence

  1. Isolate the circuit and verify that it is de-energised. Identify the conductor material, section and strand construction.
  2. Select the matching connector, tool and die combination. Strip to the required insertion length without cutting or losing strands.
  3. Insert the conductor fully and crimp in the sequence and number of compressions specified for the connector/tool system. Do not substitute a die solely because its size marking looks similar.
  4. Place the palm flat against the intended terminal, use matching hardware and tighten to the equipment connection specification. Support the cable so the palm carries no avoidable bending load.
  5. Inspect the compression, conductor retention and contact alignment. Restore suitable insulation and protection, then carry out the assembly checks before energising.
Practical answers

Frequently asked questions

What distinguishes AUS from other cable connectors?

Tinned copper tube lugs in the AUS dimensional series. The 6–1000 mm² range includes alternative stud-hole sizes and a defined overall-length schedule.

How do I select the correct AUS size?

Specify AUS construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

What should I check before ordering this series?

AUS and SC dimensions differ. Match the barrel and palm geometry as well as the cable cross-section.

Does the conductor size determine a universal current rating?

No. Connection current depends on the cable material and size, insulation temperature, terminal interface, installation conditions and verified crimp system. Select the whole circuit and connection together.

Can I use any crimping die with the same size number?

No. Die profile, tool force, connector wall thickness and conductor construction work as a system. Use the specified tool/die combination for the chosen connector.

Is the model size the same as the stud-hole diameter?

No. The conductor size identifies the cable section, while the hole dimension identifies the bolted interface. Both must suit the application.

Distributor & panel-builder inquiries

Specify the conductor.
Match the connection.

Include AUS model and construction, conductor material and size, stud-hole or joint requirements, quantities and packaging needs.

Request pricing ↗