Conector de cobre

Conector de cable de cobre de AUS

Bolas de tubo de cobre enlatado de la serie dimensional AUS. La gama de diámetros de 6 a 1000 mm² incluye tamaños de agujeros alternativos y un programa de diámetros definidos para la longitud total.

6–1000 mm²T2 copperBolted palm
AUS Copper Cable Lugs
AUS · Copper lugs
Datos técnicos

Material, connection & construction

AUS product specifications
ParámetroEspecificaciones
SerieAUS
Product formCopper Cable Lugs
Conductor / interfaceCopper conductor to bolted equipment terminal
Body materialT2 copper
Size range6–1000 mm²
Connection methodCrimped barrel with bolted palm
InsulationNon-insulated; provide application-specific joint insulation and enclosure protection
DimensionsMillimetres; conductor cross-section in mm²
FinishTin-plated copper
Copper purity≥99.9% T2 copper
Lug / sleeve material temperature range−55°C to +150°C; the cable insulation and complete connection may impose a lower limit
Selección del modelo

Modelos y dimensiones

All dimensional values are in millimetres. Conductor sizes are in mm². Use the symbols in the drawing for the selected construction.

AUS and SC dimensions differ. Match the barrel and palm geometry as well as the cable cross-section.

AUS Copper Cable Lugs construction
Product construction
AUS Copper Cable Lugs dimension symbols
Dimensional geometry · All dimensions in mm
Use the dimension symbols in this series drawing; symbols can differ between constructions.

AUS model dimensions
ModeloStud hole ØBarrel OD DBarrel ID dOverall length L
AUS-65.2/6.2/8.25.53.831.5
AUS-106.2/8.264.534.5
AUS-166.2/8.2/10.58.55.543.5
AUS-256.2/8.2/10.510748
AUS-356.2/8.2/10.5/12.512.58.252
AUS-508.2/10.5/12.514.51064
AUS-708.2/10.5/12.516.511.568
AUS-9510.5/12.51913.578
AUS-12012.5/16.52115.586
AUS-15012.5/16.523.51794
AUS-18516.525.519101
AUS-24016.52921.5111
AUS-30016.5/20.53224.5119
AUS-40016.5/20.538.527.5140
AUS-50016.5/20.54231150
AUS-63020.54434.5160
AUS-80022.55240195
AUS-100022.55844195
Aplicación y instalación

Select the complete connection

Compatibilidad de la aplicación

  • Cable ends in power-distribution and control cabinets
  • Bolted connections to compatible copper busbars and equipment terminals
  • Replacement terminations where barrel, hole and palm dimensions match

Lista de verificación de pedidos

Specify AUS construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

Secuencia de instalación

  1. Isolate the circuit and verify that it is de-energised. Identify the conductor material, section and strand construction.
  2. Select the matching connector, tool and die combination. Strip to the required insertion length without cutting or losing strands.
  3. Insert the conductor fully and crimp in the sequence and number of compressions specified for the connector/tool system. Do not substitute a die solely because its size marking looks similar.
  4. Place the palm flat against the intended terminal, use matching hardware and tighten to the equipment connection specification. Support the cable so the palm carries no avoidable bending load.
  5. Inspect the compression, conductor retention and contact alignment. Restore suitable insulation and protection, then carry out the assembly checks before energising.
Respondes de forma práctica

Preguntas frecuentes

What distinguishes AUS from other cable connectors?

Bolas de tubo de cobre enlatado de la serie dimensional AUS. La gama de diámetros de 6 a 1000 mm² incluye tamaños de agujeros alternativos y un programa de diámetros definidos para la longitud total.

How do I select the correct AUS size?

Specify AUS construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

What should I check before ordering this series?

AUS and SC dimensions differ. Match the barrel and palm geometry as well as the cable cross-section.

Does the conductor size determine a universal current rating?

No. Connection current depends on the cable material and size, insulation temperature, terminal interface, installation conditions and verified crimp system. Select the whole circuit and connection together.

Can I use any crimping die with the same size number?

No. Die profile, tool force, connector wall thickness and conductor construction work as a system. Use the specified tool/die combination for the chosen connector.

Is the model size the same as the stud-hole diameter?

No. The conductor size identifies the cable section, while the hole dimension identifies the bolted interface. Both must suit the application.

Consultas de distribuidores y constructores de paneles

Especifica el conductor.
Conecte la conexión.

Include AUS model and construction, conductor material and size, stud-hole or joint requirements, quantities and packaging needs.

Solicite un presupuesto ↗