Conector de cobre

Tubo de conexión de cable de cobre DT(G)

Cubiertas de anillo de cobre para conexiones de cable por atornillado, de 10 a 800 mm². Seleccione según sección del conductor, diámetro del orificio del barril y diámetro del agujero de la clavija.

10–800 mm²T2 copperBolted palm
DT(G) Copper Cable Lugs
DT(G) · Copper lugs
Datos técnicos

Material, connection & construction

DT(G) product specifications
ParámetroEspecificaciones
SerieDT(G)
Product formCopper Cable Lugs
Conductor / interfaceCopper conductor to bolted equipment terminal
Body materialT2 copper
Size range10–800 mm²
Connection methodCrimped barrel with bolted palm
InsulationNon-insulated; provide application-specific joint insulation and enclosure protection
DimensionsMillimetres; conductor cross-section in mm²
FinishTin-plated copper
Finish optionsBare copper / tinned copper; specify the required finish
Selección del modelo

Modelos y dimensiones

All dimensional values are in millimetres. Conductor sizes are in mm². Use the symbols in the drawing for the selected construction.

DT(G) Copper Cable Lugs construction
Product construction
DT(G) Copper Cable Lugs dimension symbols
Dimensional geometry · All dimensions in mm
Use the dimension symbols in this series drawing; symbols can differ between constructions.

DT(G) model dimensions
ModeloStud hole ØBarrel OD DBarrel ID dOverall length L
DT(G)-106.28552
DT(G)-166.29657
DT(G)-256.210762
DT(G)-358.511866
DT(G)-508.5131072
DT(G)-7010.5161280
DT(G)-9510.5181485
DT(G)-12012.5201596
DT(G)-15012.52317102
DT(G)-18514.52519114
DT(G)-24016.52721120
DT(G)-30016.53124135
DT(G)-40018.53426150
DT(G)-50020.53830170
DT(G)-63022.54535210
DT(G)-80022.55040270
Aplicación y instalación

Select the complete connection

Compatibilidad de la aplicación

  • Cable ends in power-distribution and control cabinets
  • Bolted connections to compatible copper busbars and equipment terminals
  • Replacement terminations where barrel, hole and palm dimensions match

Lista de verificación de pedidos

Specify DT(G) construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

Secuencia de instalación

  1. Isolate the circuit and verify that it is de-energised. Identify the conductor material, section and strand construction.
  2. Select the matching connector, tool and die combination. Strip to the required insertion length without cutting or losing strands.
  3. Insert the conductor fully and crimp in the sequence and number of compressions specified for the connector/tool system. Do not substitute a die solely because its size marking looks similar.
  4. Place the palm flat against the intended terminal, use matching hardware and tighten to the equipment connection specification. Support the cable so the palm carries no avoidable bending load.
  5. Inspect the compression, conductor retention and contact alignment. Restore suitable insulation and protection, then carry out the assembly checks before energising.
Respondes de forma práctica

Preguntas frecuentes

What distinguishes DT(G) from other cable connectors?

Cubiertas de anillo de cobre para conexiones de cable por atornillado, de 10 a 800 mm². Seleccione según sección del conductor, diámetro del orificio del barril y diámetro del agujero de la clavija.

How do I select the correct DT(G) size?

Specify DT(G) construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

Does the conductor size determine a universal current rating?

No. Connection current depends on the cable material and size, insulation temperature, terminal interface, installation conditions and verified crimp system. Select the whole circuit and connection together.

Can I use any crimping die with the same size number?

No. Die profile, tool force, connector wall thickness and conductor construction work as a system. Use the specified tool/die combination for the chosen connector.

Is the model size the same as the stud-hole diameter?

No. The conductor size identifies the cable section, while the hole dimension identifies the bolted interface. Both must suit the application.

Consultas de distribuidores y constructores de paneles

Especifica el conductor.
Conecte la conexión.

Include DT(G) model and construction, conductor material and size, stud-hole or joint requirements, quantities and packaging needs.