Wenzhou Changsong Electric Co., Ltd.
Catálogos y ficheros técnicosContacto e indagaciónWhatsApp
CHSOELECTRÓNICA INDUSTRIALSolicite un presupuesto 0→
Conector de cobre

SC(JGB) Mangos de cobre con entrada afilada

Conector de cobre sellado con una entrada del cable aplanada. La boca ampliada facilita la inserción del conductor, mientras que el diámetro especificado define el cuerpo de crimado.

1.5–1000 mm²T2 copperBolted palm
SC(JGB) Flared-Entry Copper Lugs
SC(JGB) · Copper lugs
Datos técnicos

Material, connection & construction

SC(JGB) product specifications
ParámetroEspecificaciones
SerieSC(JGB)
Product formFlared-Entry Copper Lugs
Conductor / interfaceCopper conductor to bolted equipment terminal
Body materialT2 copper
Size range1.5–1000 mm²
Connection methodCrimped barrel with bolted palm
InsulationNon-insulated; provide application-specific joint insulation and enclosure protection
DimensionsMillimetres; conductor cross-section in mm²
FinishTin-plated copper
Copper purity≥99.9% T2 copper
Lug / sleeve material temperature range−55°C to +150°C; the cable insulation and complete connection may impose a lower limit
Selección del modelo

Modelos y dimensiones

All dimensional values are in millimetres. Conductor sizes are in mm². Use the symbols in the drawing for the selected construction.

Slash-separated hole diameters are alternative stud-hole versions, not several holes in one lug.

SC(JGB) Flared-Entry Copper Lugs construction
Product construction
SC(JGB) Flared-Entry Copper Lugs dimension symbols
Dimensional geometry · All dimensions in mm
Use the dimension symbols in this series drawing; symbols can differ between constructions.

SC(JGB) model dimensions
ModeloStud hole ØBarrel OD DBarrel ID dOverall length L
SC(JGB)-1.54.2/5.23.51.818
SC(JGB)-2.54.2/5.2/6.242.519
SC(JGB)-45.2/6.24.83.121
SC(JGB)-65.2/6.2/8.25.53.824
SC(JGB)-106.2/8.26.84.825.5
SC(JGB)-166.2/8.2/10.57.55.530.5
SC(JGB)-256.2/8.2/10.59734
SC(JGB)-356.2/8.2/10.5/12.510.58.238
SC(JGB)-508.2/10.5/12.512.59.845
SC(JGB)-708.2/10.5/12.514.511.550
SC(JGB)-9510.5/12.517.513.855.5
SC(JGB)-12012.5/16.519.515.563
SC(JGB)-15012.5/16.52116.571
SC(JGB)-18516.523.518.878
SC(JGB)-24016.526.52192
SC(JGB)-30016.5/20.53024102
SC(JGB)-40016.5/20.53426.5113
SC(JGB)-50016.5/20.53830123
SC(JGB)-63020.54535135
SC(JGB)-80022.55039170
SC(JGB)-100022.55644200
Aplicación y instalación

Select the complete connection

Compatibilidad de la aplicación

  • Cable ends in power-distribution and control cabinets
  • Bolted connections to compatible copper busbars and equipment terminals
  • Replacement terminations where barrel, hole and palm dimensions match

Lista de verificación de pedidos

Specify SC(JGB) construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

Secuencia de instalación

  1. Isolate the circuit and verify that it is de-energised. Identify the conductor material, section and strand construction.
  2. Select the matching connector, tool and die combination. Strip to the required insertion length without cutting or losing strands.
  3. Insert the conductor fully and crimp in the sequence and number of compressions specified for the connector/tool system. Do not substitute a die solely because its size marking looks similar.
  4. Place the palm flat against the intended terminal, use matching hardware and tighten to the equipment connection specification. Support the cable so the palm carries no avoidable bending load.
  5. Inspect the compression, conductor retention and contact alignment. Restore suitable insulation and protection, then carry out the assembly checks before energising.
Respondes de forma práctica

Preguntas frecuentes

What distinguishes SC(JGB) from other cable connectors?

Conector de cobre sellado con una entrada del cable aplanada. La boca ampliada facilita la inserción del conductor, mientras que el diámetro especificado define el cuerpo de crimado.

How do I select the correct SC(JGB) size?

Specify SC(JGB) construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

What should I check before ordering this series?

Slash-separated hole diameters are alternative stud-hole versions, not several holes in one lug.

Does the conductor size determine a universal current rating?

No. Connection current depends on the cable material and size, insulation temperature, terminal interface, installation conditions and verified crimp system. Select the whole circuit and connection together.

Can I use any crimping die with the same size number?

No. Die profile, tool force, connector wall thickness and conductor construction work as a system. Use the specified tool/die combination for the chosen connector.

Is the model size the same as the stud-hole diameter?

No. The conductor size identifies the cable section, while the hole dimension identifies the bolted interface. Both must suit the application.

Consultas de distribuidores y constructores de paneles

Especifica el conductor.
Conecte la conexión.

Include SC(JGB) model and construction, conductor material and size, stud-hole or joint requirements, quantities and packaging needs.

Solicite un presupuesto ↗
WhatsApp