Copper lugs

JG Tubular Copper Cable Lugs

Compact T2 copper tube lugs with a tinned finish. JG provides a shorter overall length than the corresponding DT(G) size in this range.

10–800 mm²T2 copperBolted palm
JG Tubular Copper Cable Lugs
JG · Copper lugs
Technical data

Material, connection & construction

JG product specifications
ParameterSpecification
SeriesJG
Product formTubular Copper Cable Lugs
Conductor / interfaceCopper conductor to bolted equipment terminal
Body materialT2 copper
Size range10–800 mm²
Connection methodCrimped barrel with bolted palm
InsulationNon-insulated; provide application-specific joint insulation and enclosure protection
DimensionsMillimetres; conductor cross-section in mm²
FinishTin-plated copper
Model selection

Models & dimensions

All dimensional values are in millimetres. Conductor sizes are in mm². Use the symbols in the drawing for the selected construction.

JG Tubular Copper Cable Lugs construction
Product construction
JG Tubular Copper Cable Lugs dimension symbols
Dimensional geometry · All dimensions in mm
Use the dimension symbols in this series drawing; symbols can differ between constructions.

JG model dimensions
ModelStud hole ØBarrel OD DBarrel ID dOverall length L
JG-106.28538
JG-168.49641
JG-258.410746
JG-358.511852
JG-508.5131054
JG-7010.5161261
JG-9510.5181466
JG-12012.5201573
JG-15012.5231777
JG-18514.5251986
JG-24016.5272193
JG-30016.53124103
JG-40018.53426113
JG-50020.53830124
JG-63022.54535140
JG-80022.55040170
Application & installation

Select the complete connection

Application fit

  • Cable ends in power-distribution and control cabinets
  • Bolted connections to compatible copper busbars and equipment terminals
  • Replacement terminations where barrel, hole and palm dimensions match

Ordering checklist

Specify JG construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

Installation sequence

  1. Isolate the circuit and verify that it is de-energised. Identify the conductor material, section and strand construction.
  2. Select the matching connector, tool and die combination. Strip to the required insertion length without cutting or losing strands.
  3. Insert the conductor fully and crimp in the sequence and number of compressions specified for the connector/tool system. Do not substitute a die solely because its size marking looks similar.
  4. Place the palm flat against the intended terminal, use matching hardware and tighten to the equipment connection specification. Support the cable so the palm carries no avoidable bending load.
  5. Inspect the compression, conductor retention and contact alignment. Restore suitable insulation and protection, then carry out the assembly checks before energising.
Practical answers

Frequently asked questions

What distinguishes JG from other cable connectors?

Compact T2 copper tube lugs with a tinned finish. JG provides a shorter overall length than the corresponding DT(G) size in this range.

How do I select the correct JG size?

Specify JG construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

Does the conductor size determine a universal current rating?

No. Connection current depends on the cable material and size, insulation temperature, terminal interface, installation conditions and verified crimp system. Select the whole circuit and connection together.

Can I use any crimping die with the same size number?

No. Die profile, tool force, connector wall thickness and conductor construction work as a system. Use the specified tool/die combination for the chosen connector.

Is the model size the same as the stud-hole diameter?

No. The conductor size identifies the cable section, while the hole dimension identifies the bolted interface. Both must suit the application.

Distributor & panel-builder inquiries

Specify the conductor.
Match the connection.

Include JG model and construction, conductor material and size, stud-hole or joint requirements, quantities and packaging needs.

Request pricing ↗