CHSO / ENCLOSURE CLIMATE CONTROL

KTO 011 & KTS 011 Thermostats

Mechanical thermostats with separate NC and NO versions. KTO 011 opens on temperature rise to stop a heater; KTS 011 closes on temperature rise to start a fan or temperature alarm.

KTO 011 & KTS 011 Thermostats
KTO 011 & KTS 011 Thermostats

ORDERING CONFIGURATION

Choose contact action and dial range.

Download technical summary · CSV ↓
KTO 011 & KTS 011 Thermostats configurations
ModelContact actionTypical circuit
KTO 011NC: opens on temperature riseEnclosure heater
KTS 011NO: closes on temperature riseFilter fan or overtemperature signal

TECHNICAL DATA

Electrical and mechanical characteristics

KTO 011 & KTS 011 Thermostats technical data
ParameterSpecification
SensorThermostatic bimetal
Contact systemSnap-action contacts
Control actionKTO: NC, opens as temperature rises. KTS: NO, closes as temperature rises.
Dial setting range0–60 °C standard selection; specify alternatives separately
Switching differential7 K ±4 K; verify with the selected configuration
MountingClip for 35 mm DIN rail
Protection typeIP20; install inside a protective enclosure
Operating / storage temperature−45 to +80 °C
HumidityMaximum 90% RH, non-condensing
Case dimensions60 × 33 × 43 mm
Switching loadSpecify AC/DC voltage, resistive or inductive load, running current and inrush current
Indicator supplyNo separate supply required for the mechanical sensing element

DIMENSIONS & CONNECTIONS

Check the selected housing.

KTO 011 & KTS 011 Thermostats Heating and cooling circuit examples
Heating and cooling circuit examples · Open full drawing ↗

Listed case size: 60 × 33 × 43 mm. Confirm the final housing drawing; the available outline illustration has a conflicting depth label and is not used for mounting dimensions.

Application and installation

SELECTION SUPPORT

Questions before ordering

How should I specify KTO 011 & KTS 011?

Provide the exact model, NC/NO contact function, dial range, load voltage, running current and start-up current, quantity and destination. Include the mounting drawing or existing-unit photo for a replacement.

What is the difference between KTO and KTS?

KTO is a normally closed heating contact that opens as temperature rises. KTS is a normally open cooling contact that closes as temperature rises. Choose the function before comparing the current rating.

Which documents should accompany the enquiry?

Request the model-specific dimensional and connection drawing, electrical ratings and any compliance documents required for the destination market. Identify the sample or configuration to which they must apply.

TECHNICAL ENQUIRY

Specify the control and the load.

Send the model and operating conditions below so the contact rating, housing and required documents can be checked together.

Contact CHSO →

Include with your request

  • KTO 011 & KTS 011 Thermostats; quantity and destination
  • Thermostat: NC / NO function, temperature scale, load voltage, running current and inrush
  • Heater: required wattage, mains voltage, cabinet size and minimum ambient temperature
  • Available mounting space, existing-unit photo and required approval documents