DZ108 Copper Comb Busbar

DZ108 copper comb busbar with fork contacts, a 10 mm² conductor section and a 63 A rating.

63 A10 mm²DZ108 fork layout
DZ108 Copper Comb Busbar
DZ108 · Compact & Special Layouts
Technical data

Product specifications

Choose DZ108 by its dimensioned terminal pattern. Compare the fork or contact profile, group span, terminal heights and phase sequence with the connected device; a similar model-family name alone is not enough.

DZ108 technical specifications
ParameterSpecification
Product familyDZ108
ConductorCopper
Nominal voltage415 V
Maximum operating voltage500 V
Impulse voltage4 kV
Rated current63 A
Connection arrangementSee the pole layout and terminal geometry for each configuration
Model selection

Ratings, contact patterns & dimensions

All dimensions are in millimetres unless stated otherwise. Conductor cross-section is in mm²; the model-table width is distinct from contact tooth width.

DZ108 · DZ108 fork layout

DZ108 · DZ108 fork layout copper busbar
DZ108 · DZ108 fork layout product configuration
DZ108 · DZ108 fork layout dimensional drawing and contact arrangement
Contact geometry · Dimensions in mm
DZ108 · DZ108 fork layout model ratings
Ordering modelCopper thickness (mm)Cross-section (mm²)Rated current (A)Conductor width (mm)
DZ1081.510637
Layout designation
DZ108 fork layout
Contact-group span
55 mm
Fork outer dimension
9.01 mm
Fork opening
4.08 mm
Contact tip dimension
2.47 mm
Application & installation

Fit the complete device row

Application fit

  • Power interconnection of matching modular device groups
  • Panel assemblies with the specific DZ108 connection geometry

Ordering checklist

Choose DZ108 by its dimensioned terminal pattern. Compare the fork or contact profile, group span, terminal heights and phase sequence with the connected device; a similar model-family name alone is not enough.

Include quantities, destination and packaging requirements. For a replacement, identify the connected devices and the full contact sequence.

Installation sequence

  1. Isolate the supply and verify that the assembly is de-energised.
  2. Check the device lineup, phase and neutral sequence, contact positions and insulating profile.
  3. Use the specified finished length. Where the selected design permits cutting, remove swarf and burrs and refit matching end insulation.
  4. Seat contacts fully in the intended terminal openings and tighten to the connected device manufacturer’s specified torque.
  5. Protect unused exposed contacts, inspect end caps and verify continuity, separation of poles and conductor retention before energising.
Practical answers

Frequently asked questions

How do I specify DZ108?

Choose DZ108 by its dimensioned terminal pattern. Compare the fork or contact profile, group span, terminal heights and phase sequence with the connected device; a similar model-family name alone is not enough.

Does matching the pitch guarantee compatibility?

No. Match the terminal opening, tooth height and width, pole sequence, device spacing and insulation profile. A matching pitch alone does not establish compatibility.

What determines the usable current in the assembled panel?

Use the listed model rating together with the limits of the feeder connection, connected devices and enclosure conditions. Each pole carries its own load; tooth count does not multiply the current rating.

What information belongs in an order?

Include the full model code, layout designation, required length or tooth count, matching device series, quantity and end-cap requirements.

Distributor & panel-builder inquiries

Specify the layout.
Get the right connection.

Include DZ108 model and layout, required length or tooth count, matching device series, quantities and end-cap requirements.

Request pricing ↗