Copper lugs

OT Open-Barrel Copper Ring Terminals

Open-barrel copper terminals with a ring palm for bolted distribution connections. The open wings require a crimp tool and profile suited to this construction.

OT-10A to OT-1000ACopperBolted palm
OT Open-Barrel Copper Ring Terminals
OT · Copper lugs
Technical data

Material, connection & construction

OT product specifications
ParameterSpecification
SeriesOT
Product formOpen-Barrel Copper Ring Terminals
Conductor / interfaceCopper conductor to bolted equipment terminal
Body materialCopper
Size rangeOT-10A to OT-1000A
Connection methodCrimped barrel with bolted palm
InsulationNon-insulated; provide application-specific joint insulation and enclosure protection
DimensionsMillimetres; conductor cross-section in mm²
Model selection

Models & dimensions

All dimensional values are in millimetres. Conductor sizes are in mm². Use the symbols in the drawing for the selected construction.

The A suffix belongs to the OT model designation. It is not a stand-alone continuous-current rating for a completed cable assembly.

OT Open-Barrel Copper Ring Terminals construction
Product construction
OT Open-Barrel Copper Ring Terminals dimension symbols
Dimensional geometry · All dimensions in mm
Use the dimension symbols in this series drawing; symbols can differ between constructions.

OT model dimensions
ModelStud hole ØHLRR1Thickness A
OT-10A5.2614.54.52.8
OT-20A6.27175.52.51
OT-30A6.28.2195.83.21.2
OT-40A6.2919.56.23.51.2
OT-50A6.2921.56.53.51.2
OT-60A8.21023741.4
OT-80A8.2112584.51.5
OT-100A8.212298.551.5
OT-150A10.2123195.51.6
OT-200A10.214331061.7
OT-250A10.215.53610.56.52
OT-300A12.2164011.572
OT-400A12.218431382.2
OT-500A14.2204614.58.52.4
OT-600A16.22250.51610.52.8
OT-800A18.2266117.512.53.2
OT-1000A18.2336620.515.53.8
Application & installation

Select the complete connection

Application fit

  • Cable ends in power-distribution and control cabinets
  • Bolted connections to compatible copper busbars and equipment terminals
  • Replacement terminations where barrel, hole and palm dimensions match

Ordering checklist

Specify OT construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

Installation sequence

  1. Isolate the circuit and verify that it is de-energised. Identify the conductor material, section and strand construction.
  2. Select the matching connector, tool and die combination. Strip to the required insertion length without cutting or losing strands.
  3. Insert the conductor fully and crimp in the sequence and number of compressions specified for the connector/tool system. Do not substitute a die solely because its size marking looks similar.
  4. Place the palm flat against the intended terminal, use matching hardware and tighten to the equipment connection specification. Support the cable so the palm carries no avoidable bending load.
  5. Inspect the compression, conductor retention and contact alignment. Restore suitable insulation and protection, then carry out the assembly checks before energising.
Practical answers

Frequently asked questions

What distinguishes OT from other cable connectors?

Open-barrel copper terminals with a ring palm for bolted distribution connections. The open wings require a crimp tool and profile suited to this construction.

How do I select the correct OT size?

Specify OT construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

What should I check before ordering this series?

The A suffix belongs to the OT model designation. It is not a stand-alone continuous-current rating for a completed cable assembly.

Does the conductor size determine a universal current rating?

No. Connection current depends on the cable material and size, insulation temperature, terminal interface, installation conditions and verified crimp system. Select the whole circuit and connection together.

Can I use any crimping die with the same size number?

No. Die profile, tool force, connector wall thickness and conductor construction work as a system. Use the specified tool/die combination for the chosen connector.

Is the model size the same as the stud-hole diameter?

No. The conductor size identifies the cable section, while the hole dimension identifies the bolted interface. Both must suit the application.

Distributor & panel-builder inquiries

Specify the conductor.
Match the connection.

Include OT model and construction, conductor material and size, stud-hole or joint requirements, quantities and packaging needs.