RNB Non-insulated Ring Terminals

RNB non-insulated ring terminals provide a closed eye for bolted copper-wire connections. Select the conductor range independently from the stud hole, palm width and overall length.

0.5–400 mm²153 variantsNone
View model dimensions ↓
RNB Non-insulated Ring Terminals
PRODUCT SPECIFICATION

Built around your connection.

Conductor range
0.5–400 mm²
Conductor
Copper wire
Contact material
Copper
Insulation
None
Connection
Ring & fork
Variants
153

Selection essentials

Check stud-hole diameter d2 and palm width B separately. S, M and L variants can have different palm widths even at the same wire and stud size.

Typical applications

Control-panel studs, screw terminals and accessible bolted copper-wire connections.

COMPLETE MODEL TABLE

RNB dimensions & wire sizes.

RNB terminal dimensional drawing
RNB dimensional reference

Read the dimensions before selecting.

Check stud-hole diameter d2 and palm width B separately. S, M and L variants can have different palm widths even at the same wire and stud size.

All dimensional columns are in millimetres. Conductor sizes are cross-sectional areas, not wire diameters. The first column contains the complete ordering code.

153 model variants

RNB Non-insulated Ring Terminals — model dimensions and conductor selection
ModelWire mm²AWG / kcmilImax AHole d2 mmPalm B mmL mmF mmBarrel E mmOuter D mmBore d mm
RNB1.25-30.5–1.522–16193.25.712.64.954.83.41.7
RNBS1.25-3.50.5–1.522–16193.75.712.64.954.83.41.7
RNBM1.25-3.50.5–1.522–16193.76.614.46.34.83.41.7
RNBL1.25-3.50.5–1.522–16193.7815.874.83.41.7
RNBS1.25-40.5–1.522–16194.36.614.46.34.83.41.7
RNBL1.25-40.5–1.522–16194.3815.874.83.41.7
RNB1.25-50.5–1.522–16195.3815.874.83.41.7
RNBL1.25-50.5–1.522–16195.39.8188.54.83.41.7
RNBS1.25-60.5–1.522–16196.49.8188.54.83.41.7
RNB1.25-60.5–1.522–16196.411.621.811.14.83.41.7
RNB1.25-80.5–1.522–16198.411.621.811.14.83.41.7
RNB1.25-100.5–1.522–161910.513.625.513.94.83.41.7
RNB1.25-120.5–1.522–16191319.23116.54.83.41.7
RNB2-31.5–2.516–14273.26.612.24.34.84.12.3
RNBS2-3.51.5–2.516–14273.76.612.24.34.84.12.3
RNBM2-3.51.5–2.516–14273.76.61674.84.12.3
RNBL2-3.51.5–2.516–14273.78.516.87.754.84.12.3
RNBS2-41.5–2.516–14274.36.514.36.24.84.12.3
RNBL2-41.5–2.516–14274.38.516.87.754.84.12.3
RNB2-51.5–2.516–14275.38.516.87.754.84.12.3
RNBL2-51.5–2.516–14275.39.516.87.254.84.12.3
RNBS2-61.5–2.516–14276.41221.8114.84.12.3
RNB2-81.5–2.516–14278.41221.8114.84.12.3
RNB2-101.5–2.516–142710.513.625.513.94.84.12.3
RNB2-121.5–2.516–14271319.23116.54.84.12.3
RNB3.5-42.5–414–12374.38187.7653
RNBS3.5-52.5–414–12375.38187.7653
RNBL3.5-52.5–414–12375.31221.47.7653
RNB3.5-62.5–414–12376.41221.47.7653
RNBS5.5-3.54–612–10483.77.215.75.96.85.63.4
RNBS5.5-44–612–10484.37.215.75.96.85.63.4
RNBL5.5-44–612–10484.39.519.88.36.85.63.4
RNB5.5-54–612–10485.39.519.88.36.85.63.4
RNB5.5-64–612–10486.41225.8136.85.63.4
RNB5.5-84–612–10488.4152813.76.85.63.4
RNB5.5-104–612–104810.5152813.76.85.63.4
RNB5.5-124–612–10481319.232.4166.85.63.4
RNB8-46–108624.38.823.89.38.57.24.5
RNBS8-56–108625.38.823.811.18.57.24.5
RNBM8-56–108625.31223.89.38.57.24.5
RNBL8-56–108625.31529.813.88.57.24.5
RNBS8-66–108626.41223.89.38.57.24.5
RNBL8-66–108626.41529.813.88.57.24.5
RNB8-86–108628.41529.813.88.57.24.5
RNB8-106–1086210.51529.813.88.57.24.5
RNB8-126–10862132033.5158.57.24.5
RNB14-410–166884.31229.813.310.395.8
RNB14-510–166885.31229.813.310.395.8
RNBS14-610–166886.41229.813.310.395.8
RNBL14-610–166886.41632.813.310.395.8
RNB14-810–166888.41632.814.510.395.8
RNB14-1010–1668810.51632.814.510.395.8
RNB14-1210–1668813224119.510.395.8
RNB22-516–2541155.312.233.214.51211.57.7
RNBL22-516–2541155.316.533.713.51211.57.7
RNBS22-616–2541156.412.233.214.51211.57.7
RNBL22-616–2541156.416.533.713.51211.57.7
RNB22-816–2541158.416.533.713.51211.57.7
RNB22-1016–25411510.516.533.713.51211.57.7
RNB22-1116–25411511.52242.519.51211.57.7
RNB22-1216–254115132242.519.51211.57.7
RNB38-535–5021605.315.33918.31413.39.4
RNB38-635–5021606.415.33918.31413.39.4
RNBS38-835–5021608.415.33918.31413.39.4
RNBL38-835–5021608.42242.717.71413.39.4
RNBS38-1035–50216010.515.33918.31413.39.4
RNBL38-1035–50216010.52242.717.71413.39.4
RNB38-1135–50216011.52242.717.71413.39.4
RNB38-1235–502160132242.717.71413.39.4
RNB60-650–701/02156.42249.720.71815.411.4
RNB60-850–701/02158.42249.720.71815.411.4
RNB60-1050–701/021510.52249.720.71815.411.4
RNB60-1150–701/021511.52249.720.71815.411.4
RNB60-1250–701/0215132249.720.71815.411.4
RNB60-1450–701/0215153257.523.51815.411.4
RNB60-1650–701/0215173257.523.51815.411.4
RNB60-1850–701/0215193257.523.51815.411.4
RNB60-2050–701/0215213257.523.51815.411.4
RNB60-2250–701/0215233257.523.51815.411.4
RNB70-670–952/02356.42451201917.513.3
RNB70-870–952/02358.42451201917.513.3
RNB70-1070–952/023510.52451201917.513.3
RNB70-1170–952/023511.52451201917.513.3
RNB70-1270–952/0235132451201917.513.3
RNB70-1470–952/0235153261251917.513.3
RNB70-1670–952/0235173261251917.513.3
RNB70-1870–952/0235193261251917.513.3
RNB70-2070–952/0235213261251917.513.3
RNB70-2270–952/0235233261251917.513.3
RNB80-695–1203/02556.4275420.72019.514.5
RNB80-895–1203/02558.4275420.72019.514.5
RNB80-1095–1203/025510.5275420.72019.514.5
RNB80-1195–1203/025511.5275420.72019.514.5
RNB80-1295–1203/025513275420.72019.514.5
RNB80-1495–1203/0255153268322019.514.5
RNB80-1695–1203/0255173268322019.514.5
RNB80-1895–1203/0255193268322019.514.5
RNB80-2095–1203/0255213268322019.514.5
RNB80-2295–1203/0255233268322019.514.5
RNB100-6120–1504/03006.428.555.620.42122.116.4
RNB100-8120–1504/03008.428.555.620.42122.116.4
RNB100-10120–1504/030010.528.555.620.42122.116.4
RNB100-11120–1504/030011.528.555.620.42122.116.4
RNB100-12120–1504/03001328.555.620.42122.116.4
RNB100-14120–1504/0300153269322122.116.4
RNB100-16120–1504/0300173269322122.116.4
RNB100-18120–1504/0300193269322122.116.4
RNB100-20120–1504/0300213269322122.116.4
RNB100-22120–1504/0300233269322122.116.4
RNB150-8150–185250–300 kcmil3958.43666232726.619.5
RNB150-10150–185250–300 kcmil39510.53666232726.619.5
RNB150-11150–185250–300 kcmil39511.53666232726.619.5
RNB150-12150–185250–300 kcmil395133666232726.619.5
RNB150-14150–185250–300 kcmil395153666232726.619.5
RNB150-16150–185250–300 kcmil395173666232726.619.5
RNB150-18150–185250–300 kcmil395193681362726.619.5
RNB150-20150–185250–300 kcmil395213681362726.619.5
RNB150-22150–185250–300 kcmil395233681362726.619.5
RNB150-24150–185250–300 kcmil395253681362726.619.5
RNB150-27150–185250–300 kcmil395283681362726.619.5
RNB180-8185–240300–350 kcmil4408.438.56924.528.528.621
RNB180-10185–240300–350 kcmil44010.538.56924.528.528.621
RNB180-11185–240300–350 kcmil44011.538.56924.528.528.621
RNB180-12185–240300–350 kcmil4401338.56924.528.528.621
RNB180-14185–240300–350 kcmil4401538.56924.528.528.621
RNB180-16185–240300–350 kcmil4401738.56924.528.528.621
RNB180-18185–240300–350 kcmil4401938.586.63928.528.621
RNB180-20185–240300–350 kcmil4402138.586.63928.528.621
RNB180-22185–240300–350 kcmil4402338.586.63928.528.621
RNB180-24185–240300–350 kcmil4402538.586.63928.528.621
RNB180-27185–240300–350 kcmil4402838.586.63928.528.621
RNB200-8240–300400 kcmil4708.4447224.531.532.624
RNB200-10240–300400 kcmil47010.5447224.531.532.624
RNB200-11240–300400 kcmil47011.5447224.531.532.624
RNB200-12240–300400 kcmil47013447224.531.532.624
RNB200-14240–300400 kcmil47015447224.531.532.624
RNB200-16240–300400 kcmil47017447224.531.532.624
RNB200-18240–300400 kcmil47019449137.531.532.624
RNB200-20240–300400 kcmil47021449137.531.532.624
RNB200-22240–300400 kcmil47023449137.531.532.624
RNB200-24240–300400 kcmil47025449137.531.532.624
RNB200-27240–300400 kcmil47028449137.531.532.624
RNB325-8300–400500–600 kcmil6508.450.58833.535.537.128
RNB325-10300–400500–600 kcmil65010.550.58833.535.537.128
RNB325-11300–400500–600 kcmil65011.550.58833.535.537.128
RNB325-12300–400500–600 kcmil6501350.58833.535.537.128
RNB325-14300–400500–600 kcmil6501550.58833.535.537.128
RNB325-16300–400500–600 kcmil6501750.58833.535.537.128
RNB325-18300–400500–600 kcmil6501950.5105.74535.537.128
RNB325-20300–400500–600 kcmil6502150.5105.74535.537.128
RNB325-22300–400500–600 kcmil6502350.5105.74535.537.128
RNB325-24300–400500–600 kcmil6502550.5105.74535.537.128
RNB325-27300–400500–600 kcmil6502850.5105.74535.537.128

Dimensions are nominal and stated in millimetres. Select by conductor cross-section and the actual mating dimensions, not by color alone.

AWG and kcmil values are size references, not exact conversions of every metric cross-section.

Imax is the terminal size reference limit. The permissible circuit current also depends on wire size, ambient temperature, crimp quality and the mating terminal; use the lowest applicable limit.

The metal terminal has no insulating barrier. Assembly voltage and clearance depend on the enclosure, terminal block and any added insulation.

ASSEMBLY GUIDE

A suitable terminal needs a suitable crimp.

01 / Match

Use the stated copper conductor size. Match the stud, slot, tab, tube or pin dimensions to the receiving component.

02 / Prepare

Strip the wire to the metal barrel or tube insertion length. Keep all strands intact and inside the barrel.

03 / Crimp

Use a die intended for this terminal construction and the selected wire size. Complete the tool’s crimp cycle.

04 / Inspect

Check strand capture, barrel deformation and retention. Install to the receiving component’s tightening and clearance requirements.

RNB questions answered.

What is the RNB series used for?

RNB non-insulated ring terminals provide a closed eye for bolted copper-wire connections. Select the conductor range independently from the stud hole, palm width and overall length.

How do I choose a RNB model?

Check stud-hole diameter d2 and palm width B separately. S, M and L variants can have different palm widths even at the same wire and stud size.

Can I select the terminal by insulation color alone?

No. This series has no insulating collar. Use the conductor range, barrel dimensions and mating dimensions in the table.

How should the terminal be crimped?

Strip to the metal barrel or tube insertion length without cutting strands. Insert the conductor fully, use a die made for the terminal type and wire size, complete the crimp, then inspect strand capture and mechanical retention. Follow the receiving component’s tightening instructions.

What should I include in an enquiry?

List the complete RNB model code, quantity and conductor size. Add the stud, tab, pin or barrel dimensions relevant to your installation and your destination country.

COMPARE CONNECTION OPTIONS

Related terminal families.

BUILD YOUR TERMINAL ORDER

Specify your RNB models.

Send the complete model codes, quantities, conductor sizes and destination country.

Enquire with CHSO →