Bridges & end covers
Specify the connection pattern and number of poles. Use the model-specific bridge and end-cover references shown above. Confirm isolation between neighbouring circuits.
A clear connection.
A complete specification.
Choose the terminal function, compare conductor ranges and dimensions, then build the accessory list for your panel.
Model-specific specifications stay together. Use the filters to narrow the list; open a model reference for its profile and accessory notes.
30 models
No matching model. Clear the filters or try a shorter reference.
Dimensions: W = terminal width along the rail; D / H = horizontal / vertical envelope in the catalogue profile. All dimensions are in mm. Conductor ranges are in mm².
Single-level screw terminal blocks for point-to-point panel wiring. Compare conductor ranges and the physical envelope by model.
| CHSO model | Rigid mm² | Flexible mm² | Current A | Voltage V | W mm | D mm | H mm |
|---|---|---|---|---|---|---|---|
| CSUK1.5N | 0.2–4 | 0.2–1.5 | 32 | 690 | 5.7 | 42.5 | 42 |
| CSUK2.5B | 0.2–4 | 0.2–2.5 | 32 | 690 | 6.2 | 42.5 | 41 |
| CSUK3N | 0.2–4 | 0.2–2.5 | 32 | 800 | 5.2 | 42.5 | 46 |
| CSUK5N | 0.2–6 | 0.2–4 | 41 | 800 | 6.2 | 42.5 | 46 |
| CSUK6N | 0.2–10 | 0.2–6 | 57 | 800 | 8.2 | 42.5 | 46 |
| CSUK10N | 0.5–16 | 0.5–10 | 76 | 800 | 10.2 | 42.5 | 46 |
| CSUK16N | 2.5–25 | 4–16 | 101 | 800 | 12.2 | 42.5 | 53 |
| CSUK25N | 2.5–35 | 4–25 | 100 | 800 | 15.2 | 42.5 | 46 |
| CSUK35 | 10–35 | 10–35 | 125 | 800 | 15.3 | 56 | 51 |
| CSUKH50 | 16–50 | 25–50 | 150 | 1000 | 20 | 77.5 | 78 |
| CSUK70 | 25–70 | 35–70 | 192 | 1000 | 22.5 | 82 | 79.5 |
| CSUK95 | 25–95 | 35–95 | 232 | 1000 | 25.2 | 89 | 90.5 |
| CSUK150 | 35–150 | 50–150 | 309 | 1000 | 31 | 106 | 112 |
| CS2UK35 | 10–35 | Confirm* | 125 | 800 | 15.2 | 51 | 62 |
* CS2UK35: the flexible conductor range requires confirmation because the supplied catalogue contains inconsistent data. CSUK16N (101 A) and CSUK25N (100 A) retain the catalogue values; do not infer a rating from the model number.
W × D × H
5.7 × 42.5 × 42 mm
End cover
D-UK1.5
Connection bridge
FB1 10-5
Marker
ZB3
End fixing reference
E/UK
W × D × H
6.2 × 42.5 × 41 mm
End cover
D-UK2.5
Connection bridge
FB1 10-6
Marker
ZB6
End fixing reference
E/UK
W × D × H
5.2 × 42.5 × 46 mm
End cover
D-UK4/10
Connection bridge
FB1 10-5
Marker
ZB5
End fixing reference
E/UK
W × D × H
6.2 × 42.5 × 46 mm
End cover
D-UK4/10
Connection bridge
FB1 10-6
Marker
ZB6
End fixing reference
E/UK
W × D × H
8.2 × 42.5 × 46 mm
End cover
D-UK4/10
Connection bridge
FB1 10-8
Marker
ZB8
End fixing reference
E/UK
W × D × H
10.2 × 42.5 × 46 mm
End cover
D-UK4/10
Connection bridge
FB1 10-10
Marker
ZB10
End fixing reference
E/UK
W × D × H
12.2 × 42.5 × 53 mm
End cover
D-UK16
Connection bridge
FB1 10-16
Marker
ZB6 × 2
End fixing reference
E/UK
W × D × H
15.2 × 42.5 × 46 mm
End cover
D-UK25
Connection bridge
FB1 10-35
Marker
ZB6 × 2
End fixing reference
E/UK
W × D × H
15.3 × 56 × 51 mm
Connection bridge
FB1 10-35
Marker
ZB8 × 2
End fixing reference
E/UK
W × D × H
20 × 77.5 × 78 mm
Connection bridge
FB1 12-20 / FB1 3-20
End fixing reference
E/AL-NS 35 — confirm assembly.
W × D × H
22.5 × 82 × 79.5 mm
Connection bridge
FB1 12-20 / FB1 3-20
End fixing reference
E/AL-NS 35 — confirm assembly.
W × D × H
25.2 × 89 × 90.5 mm
Connection bridge
FB1 12-20 / FB1 3-20
End fixing reference
E/AL-NS 35 — confirm assembly.
W × D × H
15.2 × 51 × 62 mm
Flexible conductor range requires confirmation; it is inconsistent with the other model data in the supplied catalogue.
Open full profile ↗Yellow-green PE terminals for protective conductor connections. Select by conductor range, rail interface and assembly requirements.
| CHSO model | Rigid mm² | Flexible mm² | W mm | D mm | H mm |
|---|---|---|---|---|---|
| CSUSLKG 2.5 | 0.2–4 | 0.2–2.5 | 6.2 | 42.5 | 42 |
| CSUSLKG 3 | 0.2–4 | 0.2–2.5 | 5.2 | 42.5 | 47 |
| CSUSLKG 5 | 0.2–4 | 0.2–4 | 6.2 | 42.5 | 47 |
| CSUSLKG 6 | 0.2–10 | 0.2–6 | 8.2 | 42.5 | 47 |
| CSUSLKG 10 | 0.5–16 | 0.5–10 | 10.2 | 42.5 | 47 |
| CSUSLKG 16 | 2.5–25 | 4–16 | 12.2 | 42.5 | 47 |
| CSUSLKG 35 | 10–35 | 10–35 | 15.3 | 55 | 51 |
| CSUISLKG 50 | 25–50 | 16–50 | 20 | 70.5 | 83.5 |
| CS2USLKG 35 | 10–35 | 10–35 | 15.2 | 51 | 51 |
PE selection is based on the protective conductor and rail assembly. Catalogue PE current figures are not presented here as continuous load-current ratings. Confirm the CSUISLKG 50 order reference and conductor configuration.
W × D × H
6.2 × 42.5 × 42 mm
W × D × H
5.2 × 42.5 × 47 mm
W × D × H
6.2 × 42.5 × 47 mm
W × D × H
8.2 × 42.5 × 47 mm
W × D × H
10.2 × 42.5 × 47 mm
W × D × H
12.2 × 42.5 × 47 mm
W × D × H
15.3 × 55 × 51 mm
W × D × H
20 × 70.5 × 83.5 mm
Confirm the complete order reference and conductor configuration before ordering.
Open full profile ↗W × D × H
15.2 × 51 × 51 mm
Compact wiring layouts with stacked or additional connection positions. Confirm the internal circuit arrangement for the selected model.
| CHSO model | Rigid mm² | Flexible mm² | Current A | Voltage V | W mm | D mm | H mm |
|---|---|---|---|---|---|---|---|
| CSUKK 2.5 | 0.2–4 | 0.2–2.5 | 24 | 500 | 5.2 | 63 | 47.2 |
| CSUKK 5 | 0.2–6 | 0.2–4 | 41 | 500 | 6.2 | 57 | 62 |
| CSUKK 5B | 0.2–6 | 0.2–4 | 41 | 500 | 6.2 | 68.2 | 62 |
| CSUDK 4 | 0.2–4 | 0.2–2.5 | 32 | 690 | 6.2 | 64 | 47 |
W × D × H
5.2 × 63 × 47.2 mm
CSURTK/S supports test and disconnect arrangements. Confirm the connection scheme, bridge accessories and operating sequence.
| CHSO model | Rigid mm² | Flexible mm² | Current A | Voltage V | W mm | D mm | H mm |
|---|---|---|---|---|---|---|---|
| CSURTK/S | 0.5–10 | 0.5–6 | 41 | 400 | 8.2 | 72.5 | 51 |
W × D × H
8.2 × 72.5 × 51 mm
End cover
D-URTK/S
Connection bridge
FB/URTK
Confirm the switching sequence and circuit arrangement for the application.
Open full profile ↗Fuse-holder terminal formats for protected control circuits. Specify the fuse separately and verify the complete circuit rating.
| CHSO model | Rigid mm² | Flexible mm² | Current A | Voltage V | W mm | D mm | H mm |
|---|---|---|---|---|---|---|---|
| CSUDK 5-HESI | 0.2–4 | 0.2–4 | 6.3 | 800 | 8.2 | 72.5 | 56.5 |
| CSUK 10-DREHSI | 0.5–16 | 0.5–16 | 10 | 800 | 8.2 | 42 | 59 |
Electrical figures above are terminal catalogue values. Specify the fuse size, rated current, rated voltage and breaking capacity separately; the complete circuit must meet the selected fuse and terminal limits.
W × D × H
8.2 × 72.5 × 56.5 mm
Select the fuse size, fuse rating and circuit voltage separately; the terminal catalogue voltage is not a fuse breaking-capacity rating.
Open full profile ↗W × D × H
8.2 × 42 × 59 mm
Select the fuse size, fuse rating and circuit voltage separately; the terminal catalogue voltage is not a fuse breaking-capacity rating.
Open full profile ↗The CSV uses the same model data and confirmation notes as this page.
Match accessories to the chosen terminal model. References shown in the profiles are selection aids; confirm quantities and supply scope in the quotation.
Specify the connection pattern and number of poles. Use the model-specific bridge and end-cover references shown above. Confirm isolation between neighbouring circuits.
Specify printed numbering and marker format. CSUBE/D has a listed width of 15 mm; CSB1 has a listed width of 10 mm. Match ZB markers to the selected terminal.
E/UK, E/AL-NS 35 and EUK/B are catalogue fixing references. TS-K separation plates are shown for the smaller feed-through terminals. Confirm the rail profile and complete assembly before ordering.
Choose the connection function first, then compare rigid and flexible conductor ranges, the model-specific electrical data and the physical dimensions. Add the correct end covers, jumpers, markers and rail-fixing accessories to the order.
No. Catalogue voltage values differ by model. Use the individual model table. For fuse terminals, confirm the fuse rating, breaking capacity and circuit voltage separately; a terminal-body voltage does not establish the rating of the complete fused circuit.
Use the protective earth section to compare conductor ranges and dimensions. Confirm the rail type, protective conductor arrangement and complete assembly requirements. The table does not present PE catalogue current figures as continuous load-current ratings.
The listed end covers, connection bridges and markers are selection references, not a statement that they are included. Specify each required accessory and quantity in the RFQ. Confirm the matching end stop and mounting rail for the assembly.
Request model-specific material, stripping length, tightening torque, operating-temperature and compliance documents when ordering. These details are not established by the supplied model tables, and no blanket certification claim is made for this range.
Send the CHSO model, quantities, conductor type and cross-section, circuit voltage and current, mounting rail, accessories, marking requirements and delivery destination. For fuse or test terminals, include the circuit arrangement and required fuse specification.
Send your models, quantities and accessory requirements for a coordinated quotation.