DZL3 Residual Current Circuit Breakers
Choose DZL3 by rated current, pole count and residual operating current. These RCCBs provide residual-current protection; coordinate them with separate overcurrent protection.
At a glance
Specifications & model comparison
- Rated currents
- 10 / 16 / 25 / 32 / 40 / 63 A
- Poles
- 2P / 4P
- Residual operating current
- 10 / 30 / 100 / 300 mA
- Residual-current off-time
- ≤0.1 s
- Voltage
- 240 (220) V / 415 (380) V AC
- Frequency
- 50/60 Hz
| Configuration | Poles | Rated current (A) | Residual operating current (mA) | Enquiry |
|---|---|---|---|---|
| DZL3 / 2P / 10 A | 2P | 10 | 10, 30, 100, 300 | Select for RFQ → |
| DZL3 / 2P / 16 A | 2P | 16 | 10, 30, 100, 300 | Select for RFQ → |
| DZL3 / 2P / 25 A | 2P | 25 | 10, 30, 100, 300 | Select for RFQ → |
| DZL3 / 2P / 32 A | 2P | 32 | 10, 30, 100, 300 | Select for RFQ → |
| DZL3 / 2P / 40 A | 2P | 40 | 10, 30, 100, 300 | Select for RFQ → |
| DZL3 / 2P / 63 A | 2P | 63 | 10, 30, 100, 300 | Select for RFQ → |
| DZL3 / 4P / 10 A | 4P | 10 | 10, 30, 100, 300 | Select for RFQ → |
| DZL3 / 4P / 16 A | 4P | 16 | 10, 30, 100, 300 | Select for RFQ → |
| DZL3 / 4P / 25 A | 4P | 25 | 10, 30, 100, 300 | Select for RFQ → |
| DZL3 / 4P / 32 A | 4P | 32 | 10, 30, 100, 300 | Select for RFQ → |
| DZL3 / 4P / 40 A | 4P | 40 | 10, 30, 100, 300 | Select for RFQ → |
| DZL3 / 4P / 63 A | 4P | 63 | 10, 30, 100, 300 | Select for RFQ → |
Include the required pole count, electrical configuration and accessories in your enquiry. Configuration descriptions do not replace the complete ordering code.
Mechanical reference
Outline & mounting dimensions
Before ordering
Specify the configuration
- Specify rated current and residual operating current as separate values; they have different functions.
- Use appropriate upstream short-circuit and overload protection. An RCCB is not an RCBO.
- Do not infer residual-current waveform classification from the model name; state the required waveform performance in the enquiry.
- Match the 2P or 4P terminal arrangement and mounting drawing before selecting the enclosure.
Selection questions
Practical answers for purchasing
Is DZL3 an RCBO with built-in overcurrent protection?
No. It is an RCCB. Select and coordinate separate short-circuit and overload protection.