LA37 Pushbuttons & Control Switches

Flush and raised buttons, illuminated heads, mushroom operators and two selector styles share a 22 mm panel format with 1NO + 1NC contact configurations.

22 mm format1NO + 1NCMomentary / maintained
LA37 Pushbuttons & Control Switches
LA37 · 15 configurations
Technical overview

Common specifications

Use the model table below for the action, contact arrangement and head options of each configuration.

LA37 series specifications
ParameterSpecification
SeriesLA37
InstallationPanel-mounted, 22 mm operator format
Contacts in listed configurations1NO + 1NC
Head stylesFlush, raised, mushroom, illuminated, selector and key-operated
Button actionsMomentary and maintained options
Selector positions2 and 3 positions
Standard button cap choicesWhite / black / green / red / yellow / blue
Mushroom / illuminated cap choicesGreen / red / yellow
Lamp selectionSeparate neon / LED voltage versions within the 6–380 V range
Dimension unitsmm; use the matching operator and contact-block drawing
Configuration directory

Models, functions & dimensions

Open a control group to view its product image, dimensions and model table. Colour choices stay within the model entry.

15 model configurations

Flush pushbuttonsFlush pushbuttons2 configurations · Pushbutton
Flush pushbuttons
Flush pushbuttons
Flush pushbuttons dimensional drawing in millimetres
Assembly dimensions · mm

6 mm maximum panel thickness; 13.2 mm front projection; 50 mm rear depth in the illustrated assembly.

LA37 · Flush pushbuttons
ModelOperating action / layoutContactsColour / legendIllumination
LA37-11Momentary1NO + 1NCWhite / black / green / red / yellow / blueNot illuminated
LA37-11ZMaintained1NO + 1NCWhite / black / green / red / yellow / blueNot illuminated
Raised pushbuttonsRaised pushbuttons2 configurations · Pushbutton
Raised pushbuttons
Raised pushbuttons
Raised pushbuttons dimensional drawing in millimetres
Assembly dimensions · mm

6 mm maximum panel thickness; 19 mm front projection; 50 mm rear depth in the illustrated assembly.

LA37 · Raised pushbuttons
ModelOperating action / layoutContactsColour / legendIllumination
LA37-11GMomentary1NO + 1NCWhite / black / green / red / yellow / blueNot illuminated
LA37-11GZMaintained1NO + 1NCWhite / black / green / red / yellow / blueNot illuminated
Mushroom headsMushroom heads2 configurations · Mushroom

Ø40 mm heads; select illuminated or non-illuminated construction.

Mushroom heads
Mushroom heads
Mushroom heads dimensional drawing in millimetres
Assembly dimensions · mm
LA37 · Mushroom heads
ModelOperating action / layoutContactsColour / legendIllumination
LA37-11MMomentary1NO + 1NCGreen / red / yellowNot illuminated
LA37-11MDIlluminated mushroom1NO + 1NCGreen / red / yellowNeon / LED; 6–380 V version range
Twist-release mushroomTwist-release mushroom1 configuration · Latching stop
Twist-release mushroom
Twist-release mushroom
Twist-release mushroom dimensional drawing in millimetres
Assembly dimensions · mm
LA37 · Twist-release mushroom
ModelOperating action / layoutContactsColour / legendIllumination
LA37-11ZSMaintained; twist release1NO + 1NCGreen / red / yellowNot illuminated
Illuminated pushbuttonsIlluminated pushbuttons2 configurations · Illuminated

Choose a single lamp supply version. Contact action and illumination are separate functions.

Illuminated pushbuttons
Illuminated pushbuttons
Illuminated pushbuttons dimensional drawing in millimetres
Assembly dimensions · mm
LA37 · Illuminated pushbuttons
ModelOperating action / layoutContactsColour / legendIllumination
LA37-11DMomentary1NO + 1NCGreen / red / yellowNeon / LED; 6–380 V version range
LA37-11DZMaintained1NO + 1NCGreen / red / yellowNeon / LED; 6–380 V version range
Handle selectorsHandle selectors2 configurations · Selector

Select the required number of switch positions.

Handle selectors
Handle selectors
Handle selectors dimensional drawing in millimetres
Assembly dimensions · mm
LA37 · Handle selectors
ModelOperating action / layoutContactsColour / legendIllumination
LA37-11X/22-position selection1NO + 1NCBlackNot illuminated
LA37-11X/33-position selection1NO + 1NCBlackNot illuminated
Alternative-handle selectorsAlternative-handle selectors2 configurations · Selector

XB versions have the alternative handle profile shown here.

Alternative-handle selectors
Alternative-handle selectors
Alternative-handle selectors dimensional drawing in millimetres
Assembly dimensions · mm
LA37 · Alternative-handle selectors
ModelOperating action / layoutContactsColour / legendIllumination
LA37-11XB/22-position selection1NO + 1NCBlackNot illuminated
LA37-11XB/33-position selection1NO + 1NCBlackNot illuminated
Key-operated selectorsKey-operated selectors2 configurations · Key selector
Key-operated selectors
Key-operated selectors
Key-operated selectors dimensional drawing in millimetres
Assembly dimensions · mm
LA37 · Key-operated selectors
ModelOperating action / layoutContactsColour / legendIllumination
LA37-11Y/22-position selection1NO + 1NCKey-operatedNot illuminated
LA37-11Y/33-position selection1NO + 1NCKey-operatedNot illuminated

NO = normally open. NC = normally closed. Dimensions are in mm. Illustrations show the stated construction; contact assemblies and lamp versions affect installation depth.

Application & assembly

Select the complete control arrangement

Application fit

  • Start, stop, reset or jog commands on machinery panels.
  • Local mode selection and keyed control access.
  • Visual indication combined with an operator where an illuminated version is selected.

Ordering checklist

Specify the complete LA37 model, head style and colour, required action, contact arrangement and lamp voltage if illuminated. Check panel thickness, rear contact depth and wiring clearance.

Installation sequence

  1. Isolate the control circuit before assembly or wiring.
  2. Check the selected operator and enclosure dimensions, including rear clearance and wiring access.
  3. Fit the matching operator and contact assembly; wire according to the terminal markings and circuit design.
  4. Check contact operation, return or release action and lamp supply before commissioning.
Practical answers

Frequently asked questions

What is the difference between LA37-11 and LA37-11Z?

LA37-11 is momentary and returns after release. LA37-11Z is maintained and retains its switched state until reset.

What does 1NO + 1NC mean?

One normally open and one normally closed contact are included in the listed configuration. Normal refers to the unactuated state, not to the colour of the button.

How do I choose LA37 selector positions?

Choose /2 for a two-position operator or /3 for three positions. Specify the required switching sequence and return action as part of the control design.

How do X and XB selectors differ?

They use different handle profiles. Compare the front projection and handle geometry in the two selector drawings before choosing a panel layout.

Panel builders & distributors

Define the action.
Specify the complete control.

Send LA37 model, operator layout, contact combination, colours or legends, lamp supply and quantities.

Request pricing →