PRIVATE DESIGN PREVIEW Product data and supply terms are being verified. RFQ lists stay in this browser.
Wenzhou Changsong Electric Co., Ltd.
Catalogs & technical filesContact & inquiryEN
CHSOINDUSTRIAL ELECTRICALRequest a quote 0→
Home/Protection & Power/Circuit Breakers/DZ47N-63

Miniature circuit breakers

DZ47N-63 Miniature Circuit Breakers

Compare DZ47N-63 rated-current options, pole arrangements and trip curves for AC distribution circuits. Review the breaking capacity for the exact configuration before ordering.

DZ47N-63 Miniature Circuit Breakers — series reference view
Series reference • configuration varies by model

At a glance

Specifications & model comparison

Rated currents
6 / 10 / 16 / 20 / 25 / 32 / 40 / 50 / 63 A
Poles
1P / 2P / 3P / 4P
Voltage
230/400 V AC (1P); 400 V AC (2–4P)
Frequency
50/60 Hz
Trip curve
C / D
Breaking capacity Icn
Depends on curve and current
DZ47N-63 Miniature Circuit Breakers — specification comparison
SelectionRated current (A)PolesTrip curveBreaking capacity IcnEnquiry
DZ47N-63 / 6 A61P / 2P / 3P / 4PC / DC: 6 kA; D: 4 kASelect for RFQ →
DZ47N-63 / 10 A101P / 2P / 3P / 4PC / DC: 6 kA; D: 4 kASelect for RFQ →
DZ47N-63 / 16 A161P / 2P / 3P / 4PC / DC: 6 kA; D: 4 kASelect for RFQ →
DZ47N-63 / 20 A201P / 2P / 3P / 4PC / DC: 6 kA; D: 4 kASelect for RFQ →
DZ47N-63 / 25 A251P / 2P / 3P / 4PC / DC: 6 kA; D: 4 kASelect for RFQ →
DZ47N-63 / 32 A321P / 2P / 3P / 4PC / DC: 6 kA; D: 4 kASelect for RFQ →
DZ47N-63 / 40 A401P / 2P / 3P / 4PC / DC: specify required rating; D: 4 kASelect for RFQ →
DZ47N-63 / 50 A501P / 2P / 3P / 4PC / DC: 4 kA; D: 4 kASelect for RFQ →
DZ47N-63 / 63 A631P / 2P / 3P / 4PC / DC: 4 kA; D: 4 kASelect for RFQ →

Include the required pole count, electrical configuration and accessories in your enquiry. Configuration descriptions do not replace the complete ordering code.

Mechanical reference

Outline & mounting dimensions

DZ47N-63 outline and mounting dimensions in millimetres
Dimensions in mm. Match the frame and configuration shown. Open full-size drawing ↗

Before ordering

Specify the configuration

  1. Specify rated current, pole arrangement, circuit voltage, trip curve and quantity.
  2. Match the required breaking capacity to the selected current and curve; the series name alone is insufficient.
  3. For a 40 A C-curve requirement, state the required short-circuit rating in the enquiry so the exact configuration can be specified.
  4. The listed ordering options are C and D curves. B-curve references in generic trip-characteristic tables are not treated as ordering options.
  5. Check conductor size, terminal connection and enclosure space for the exact pole configuration.

Selection questions

Practical answers for purchasing

What information identifies the DZ47N-63 configuration?

Provide the current rating, pole arrangement, operating voltage and trip curve. Include the required breaking capacity and quantity.

Request a quote

Build a clear enquiry.

Select a series and add the electrical details your purchasing team needs confirmed.

This tool prepares enquiry text. Copy the summary and send it through our contact page.

Contact CHSO →

No enquiry is sent automatically.