Miniature circuit breakers
DZ47-63 Miniature Circuit Breakers
Compare DZ47-63 rated-current options, pole arrangements and trip curves for AC distribution circuits. Rated short-circuit breaking capacity: 4.5 kA.
At a glance
Specifications & model comparison
- Rated currents
- 6 / 10 / 16 / 20 / 25 / 32 / 40 / 50 / 63 A
- Poles
- 1P / 2P / 3P / 4P
- Voltage
- 230/400 V AC (1P); 400 V AC (2–4P)
- Frequency
- 50/60 Hz
- Trip curve
- C / D
- Breaking capacity Icn
- 4.5 kA
| Selection | Rated current (A) | Poles | Trip curve | Breaking capacity Icn | Enquiry |
|---|---|---|---|---|---|
| DZ47-63 / 6 A | 6 | 1P / 2P / 3P / 4P | C / D | 4.5 kA | Select for RFQ → |
| DZ47-63 / 10 A | 10 | 1P / 2P / 3P / 4P | C / D | 4.5 kA | Select for RFQ → |
| DZ47-63 / 16 A | 16 | 1P / 2P / 3P / 4P | C / D | 4.5 kA | Select for RFQ → |
| DZ47-63 / 20 A | 20 | 1P / 2P / 3P / 4P | C / D | 4.5 kA | Select for RFQ → |
| DZ47-63 / 25 A | 25 | 1P / 2P / 3P / 4P | C / D | 4.5 kA | Select for RFQ → |
| DZ47-63 / 32 A | 32 | 1P / 2P / 3P / 4P | C / D | 4.5 kA | Select for RFQ → |
| DZ47-63 / 40 A | 40 | 1P / 2P / 3P / 4P | C / D | 4.5 kA | Select for RFQ → |
| DZ47-63 / 50 A | 50 | 1P / 2P / 3P / 4P | C / D | 4.5 kA | Select for RFQ → |
| DZ47-63 / 63 A | 63 | 1P / 2P / 3P / 4P | C / D | 4.5 kA | Select for RFQ → |
Include the required pole count, electrical configuration and accessories in your enquiry. Configuration descriptions do not replace the complete ordering code.
Mechanical reference
Outline & mounting dimensions
Before ordering
Specify the configuration
- Specify rated current, pole arrangement, circuit voltage, trip curve and quantity.
- Rated short-circuit breaking capacity is 4.5 kA for the listed configurations.
- The listed ordering options are C and D curves. B-curve references in generic trip-characteristic tables are not treated as ordering options.
- Check conductor size, terminal connection and enclosure space for the exact pole configuration.
Selection questions
Practical answers for purchasing
What information identifies the DZ47-63 configuration?
Provide the current rating, pole arrangement, operating voltage and trip curve. Include the required breaking capacity and quantity.
Request a quote
Build a clear enquiry.
Select a series and add the electrical details your purchasing team needs confirmed.
This tool prepares enquiry text. Copy the summary and send it through our contact page.
Contact CHSO →