Miniature circuit breakers

DZ47-63 Miniature Circuit Breakers

Compare DZ47-63 rated-current options, pole arrangements and trip curves for AC distribution circuits. Rated short-circuit breaking capacity: 4.5 kA.

DZ47-63 Miniature Circuit Breakers — series reference view
Series reference • configuration varies by model

At a glance

Specifications & model comparison

Rated currents
6 / 10 / 16 / 20 / 25 / 32 / 40 / 50 / 63 A
Poles
1P / 2P / 3P / 4P
Voltage
230/400 V AC (1P); 400 V AC (2–4P)
Frequency
50/60 Hz
Trip curve
C / D
Breaking capacity Icn
4.5 kA
DZ47-63 Miniature Circuit Breakers — specification comparison
SelectionRated current (A)PolesTrip curveBreaking capacity IcnEnquiry
DZ47-63 / 6 A61P / 2P / 3P / 4PC / D4.5 kASelect for RFQ →
DZ47-63 / 10 A101P / 2P / 3P / 4PC / D4.5 kASelect for RFQ →
DZ47-63 / 16 A161P / 2P / 3P / 4PC / D4.5 kASelect for RFQ →
DZ47-63 / 20 A201P / 2P / 3P / 4PC / D4.5 kASelect for RFQ →
DZ47-63 / 25 A251P / 2P / 3P / 4PC / D4.5 kASelect for RFQ →
DZ47-63 / 32 A321P / 2P / 3P / 4PC / D4.5 kASelect for RFQ →
DZ47-63 / 40 A401P / 2P / 3P / 4PC / D4.5 kASelect for RFQ →
DZ47-63 / 50 A501P / 2P / 3P / 4PC / D4.5 kASelect for RFQ →
DZ47-63 / 63 A631P / 2P / 3P / 4PC / D4.5 kASelect for RFQ →

Include the required pole count, electrical configuration and accessories in your enquiry. Configuration descriptions do not replace the complete ordering code.

Mechanical reference

Outline & mounting dimensions

DZ47-63 outline and mounting dimensions in millimetres
Dimensions in mm. Match the frame and configuration shown. Open full-size drawing ↗

Before ordering

Specify the configuration

  1. Specify rated current, pole arrangement, circuit voltage, trip curve and quantity.
  2. Rated short-circuit breaking capacity is 4.5 kA for the listed configurations.
  3. The listed ordering options are C and D curves. B-curve references in generic trip-characteristic tables are not treated as ordering options.
  4. Check conductor size, terminal connection and enclosure space for the exact pole configuration.

Selection questions

Practical answers for purchasing

What information identifies the DZ47-63 configuration?

Provide the current rating, pole arrangement, operating voltage and trip curve. Include the required breaking capacity and quantity.

Request a quote

Build a clear enquiry.

Select a series and add the electrical details your purchasing team needs confirmed.

This tool prepares enquiry text. Copy the summary and send it through our contact page.

Contact CHSO →

No enquiry is sent automatically.