Sensors
TRC-Cylindrical type
Industrial sensors detect a target and provide a control signal. Select the sensing principle, target material, mounting arrangement, supply and output interface.
Target, mounting position and control input determine the sensor configuration.
Saved in this browser. No message is sent.
SELECTION GUIDE
Select the configuration for your application.
- 01
Target & sensing distance
- 02
Flush / non-flush mounting
- 03
PNP / NPN and NO / NC
- 04
Supply & cable / connector
Technical data & product views
| TRC08-1.5DN TRC08-1.5DN2 TRC08-1.5DP TRC08-1.5DP2 | TRC08-2DN TRC08-2DN2 TRC08-2DP TRC08-2DP2 | TRC12-2DN TRC12-2DN2 TRC12-2DP TRC12-2DP2 | TRC12-4DN TRC12-4DN2 TRC12-4DP TRC12-4DP2 | TRC18-5DN TRC18-5DN2 TRC18-5DP TRC18-5DP2 | TRC18-8DN TRC18-8DN2 TRC18-8DP TRC18-8DP2 | TRC30-10DN TRC30-10DN2 TRC30-10DP TRC30-10DP2 | TRC30-15DN TRC30-15DN2 TRC30-15DP TRC30-15DP2 |
| TRC12-2DO TRC12-2DC | TRC12-4DO TRC12-4DC | TRC18-5DO TRC18-5DC | TRC18-8DO TRC18-8DC | TRC30-10D0 TR030-10DC | TRC30-15DO TRC30-16DC | ||
| TRC12-2AO TRC12-2AC | TRC12-4AO TRC12-4AC | TRC18-5AO TRC18-5AC | TRC18-8AO TRC18-8AC | TR030-10AO TR030-10AC | TRC30-15AO TRC30-15AC | ||
| 1.5mm±10% | 2mm±10% | 2mm±10% | 4mm±10% | 5mm±10% | 8mm±10% | 10mm±10% | 15mm±10% |
| 0 to 1mm | 0 to 1.4mm | 0 to1.4mm | 0 to 2.8mm | 0 to 3.5mm | 0 to 5.6mm | 0 to 7mm | 0 to 10,5mm |
| Iron 12x12x1mm | Iron 12x12x1mm | Iron 18x18x1mm | Iron 18x18x1mm | Iron 30x30x1mm | Iron 30x30x1mm | ||
| Max.10% of detecting distance | |||||||
|---|---|---|---|---|---|---|---|
| DC3-wire type:12-24VDC(5-30VDC) DC2-wire type:12-30VDC AC2-wire type:90-250VAC | |||||||
| D03-wire type:Max.12mA DC2-wire type:Max.0.9mA AC2-wire type:Max.2.2mA | |||||||
| 800HZ | 800HZ | 600HZ | 400HZ | 300HZ | 200HZ | 200HZ | 100HZ |
| 20HZ | |||||||
| DC 3-wire type:Max.1.5V DC 2-wire type:Max.6V AC 2-wire type:Max.10V | |||||||
| DC 3-wire type:Max.200mA DC 2-wire type:Max.100mA AC 2-wire type:Max.200mA | |||||||
| Reverse polarity protection,Surge absorber,Short circuit protection:M12 M18 M30 DC3-wire type | |||||||
| Power supply indicator:Green LED, Operating indicator:RedLED | |||||||
| Min.50MΩ (500VDC) | |||||||
| 1500VAC 50/60HZ for1minute | |||||||
| 1 mm amplitude at frequency of 10 to 55HZ in each of X,Y,Z directions for 2 hours | |||||||
| 500m/s²(50G)X,Y,Z directions for 3times | |||||||
| -25 to 70℃(non-freezing condition) | |||||||
| 35 to 95% RH | |||||||
| Case:brass,Detecting surface:ABS | |||||||
TRC-Cylindrical type
Specify your configuration.
Include the model, quantity and destination. For replacement parts, attach the existing label and installation drawing.
YOUR REQUIREMENTS
Make the inquiry specific.
Target material; sensing distance; output type; supply; connection style.
Saved in this browser. No message is sent.