Air circuit breakers
AW45 Air Circuit Breakers
Compare 2000–6300 A frames for low-voltage switchboards. Select rated current, 3 or 4 poles, fixed or withdrawable construction, and the required controller and releases.
На первый взгляд
Технические характеристики и сравнение моделей
- Максимальный ток
- 630–6300 A across listed frames
- Rated voltage
- 400 / 690 V AC
- Поляки
- 3P / 4P
- Frequency
- 50/60 Hz
- Mounting
- Fixed / withdrawable
- Температура окружающей среды
- −5 to +40 °C; 24 h average ≤35 °C
| Frame | Rated currents (A) | Icu 400 / 690 V (kA) | Ics = Icw 400 / 690 V (kA) | Запрос |
|---|---|---|---|---|
| AW45-2000 | 630, 800, 1000, 1250, 1600, 2000 | 80 / 50 | 50 / 40 | Выберите пункт «RFQ» → |
| AW45-3200 | 2000, 2500, 3200 | 100 / 65 | 80 / 50 | Выберите пункт «RFQ» → |
| AW45-4000 | 2000, 2500, 3200, 4000 | 100 / 65 | 80 / 50 | Выберите пункт «RFQ» → |
| AW45-6300 | 4000, 5000, 6300 | 120 / 80 | 100 / 65 | Выберите пункт «RFQ» → |
В свой запрос включите необходимый объем секций, электрическую конфигурацию и принадлежности. Описания конфигурации не заменяют полный код заказа.
Mechanical reference
Outline & mounting dimensions
Перед заказом
Укажите конфигурацию
- Specify the frame and rated current separately. Choose 3P or 4P and the neutral rating (50% In or 100% In) for the selected configuration.
- Select fixed or withdrawable construction and match the panel cut-out, busbar arrangement and mounting drawing.
- Specify the standard M controller or H communication controller, and required long-delay, short-delay, instantaneous and earth-fault protection settings.
- For shunt release, undervoltage release and closing electromagnet, state the required supply: AC 220 V, AC 380 V, DC 110 V or DC 220 V.
- Undervoltage release options include instantaneous and delayed operation (1, 3 or 5 s). Confirm auxiliary contact arrangement and energy-storage motor configuration.
- Installation altitude ≤2000 m; pollution degree III; install within 5° of vertical.
Вопросы по отбору
Практические ответы на вопросы покупки
Does the frame current identify the complete AW45 breaker?
No. Rated current, pole count, neutral rating, mounting type, controller, release supply and accessories also form part of the ordering configuration.
Are the 400 V and 690 V short-circuit ratings the same?
No. The comparison table lists separate values for each operating voltage.
Запросите предложение
Создайте четкий запрос.
Выберите серию и добавьте электротехнические характеристики, подтверждение которых необходимо вашей команде по закупкам.
Это приложение готовит запрос на запросы. Скопируйте резюме и отправьте его по нашей контактной странице.
Свяжитесь с CHSO →