AW45 Air Circuit Breakers

Compare 2000–6300 A frames for low-voltage switchboards. Select rated current, 3 or 4 poles, fixed or withdrawable construction, and the required controller and releases.

AW45 Air Circuit Breakers — series reference view
Ссылка на серию • конфигурация варьируется в зависимости от модели

На первый взгляд

Технические характеристики и сравнение моделей

Максимальный ток
630–6300 A across listed frames
Rated voltage
400 / 690 V AC
Поляки
3P / 4P
Frequency
50/60 Hz
Mounting
Fixed / withdrawable
Температура окружающей среды
−5 to +40 °C; 24 h average ≤35 °C
AW45 Air Circuit Breakers — specification comparison
FrameRated currents (A)Icu 400 / 690 V (kA)Ics = Icw 400 / 690 V (kA)Запрос
AW45-2000630, 800, 1000, 1250, 1600, 200080 / 5050 / 40Выберите пункт «RFQ» →
AW45-32002000, 2500, 3200100 / 6580 / 50Выберите пункт «RFQ» →
AW45-40002000, 2500, 3200, 4000100 / 6580 / 50Выберите пункт «RFQ» →
AW45-63004000, 5000, 6300120 / 80100 / 65Выберите пункт «RFQ» →

В свой запрос включите необходимый объем секций, электрическую конфигурацию и принадлежности. Описания конфигурации не заменяют полный код заказа.

Mechanical reference

Outline & mounting dimensions

AW45-2000 outline and mounting dimensions in millimetres
Dimensions in mm. Match the frame and configuration shown. Open full-size drawing ↗
AW45-3200 outline and mounting dimensions in millimetres
Dimensions in mm. Match the frame and configuration shown. Open full-size drawing ↗
AW45-LARGE outline and mounting dimensions in millimetres
Dimensions in mm. Match the frame and configuration shown. Open full-size drawing ↗

Перед заказом

Укажите конфигурацию

  1. Specify the frame and rated current separately. Choose 3P or 4P and the neutral rating (50% In or 100% In) for the selected configuration.
  2. Select fixed or withdrawable construction and match the panel cut-out, busbar arrangement and mounting drawing.
  3. Specify the standard M controller or H communication controller, and required long-delay, short-delay, instantaneous and earth-fault protection settings.
  4. For shunt release, undervoltage release and closing electromagnet, state the required supply: AC 220 V, AC 380 V, DC 110 V or DC 220 V.
  5. Undervoltage release options include instantaneous and delayed operation (1, 3 or 5 s). Confirm auxiliary contact arrangement and energy-storage motor configuration.
  6. Installation altitude ≤2000 m; pollution degree III; install within 5° of vertical.

Вопросы по отбору

Практические ответы на вопросы покупки

Does the frame current identify the complete AW45 breaker?

No. Rated current, pole count, neutral rating, mounting type, controller, release supply and accessories also form part of the ordering configuration.

Are the 400 V and 690 V short-circuit ratings the same?

No. The comparison table lists separate values for each operating voltage.