Wenzhou Changsong Electric Co., Ltd.
Catálogos y ficheros técnicosContacto e indagaciónWhatsApp
CHSOELECTRÓNICA INDUSTRIALSolicite un presupuesto 0→
Inicio/Protección y Poder/Disyuntores/AW45

Disyuntores de circuito eléctrico

Disyuntores de circuito de aire AW45

Compare 2000–6300 A frames for low-voltage switchboards. Select rated current, 3 or 4 poles, fixed or withdrawable construction, and the required controller and releases.

AW45 Air Circuit Breakers — series reference view
Referencia de la serie • La configuración varía según el modelo

En una vista rápida

Especificaciones y comparación de modelos

Corriente nominal
630–6300 A across listed frames
Rated voltage
400 / 690 V AC
Polacos
3P / 4P
Frequency
50/60 Hz
Mounting
Fixed / withdrawable
Temperatura ambiente
−5 to +40 °C; 24 h average ≤35 °C
AW45 Air Circuit Breakers — specification comparison
FrameRated currents (A)Icu 400 / 690 V (kA)Ics = Icw 400 / 690 V (kA)Solicitud
AW45-2000630, 800, 1000, 1250, 1600, 200080 / 5050 / 40Seleccione para RFQ →
AW45-32002000, 2500, 3200100 / 6580 / 50Seleccione para RFQ →
AW45-40002000, 2500, 3200, 4000100 / 6580 / 50Seleccione para RFQ →
AW45-63004000, 5000, 6300120 / 80100 / 65Seleccione para RFQ →

Incluya en su solicitud el número de postes necesarios, la configuración eléctrica y los accesorios. Las descripciones de configuración no sustituyen al código completo de pedido.

Mechanical reference

Outline & mounting dimensions

AW45-2000 outline and mounting dimensions in millimetres
Dimensions in mm. Match the frame and configuration shown. Open full-size drawing ↗
AW45-3200 outline and mounting dimensions in millimetres
Dimensions in mm. Match the frame and configuration shown. Open full-size drawing ↗
AW45-LARGE outline and mounting dimensions in millimetres
Dimensions in mm. Match the frame and configuration shown. Open full-size drawing ↗

Antes de ordenar

Especifica la configuración

  1. Specify the frame and rated current separately. Choose 3P or 4P and the neutral rating (50% In or 100% In) for the selected configuration.
  2. Select fixed or withdrawable construction and match the panel cut-out, busbar arrangement and mounting drawing.
  3. Specify the standard M controller or H communication controller, and required long-delay, short-delay, instantaneous and earth-fault protection settings.
  4. For shunt release, undervoltage release and closing electromagnet, state the required supply: AC 220 V, AC 380 V, DC 110 V or DC 220 V.
  5. Undervoltage release options include instantaneous and delayed operation (1, 3 or 5 s). Confirm auxiliary contact arrangement and energy-storage motor configuration.
  6. Installation altitude ≤2000 m; pollution degree III; install within 5° of vertical.

Preguntas de selección

Respondes prácticos a la compra

Does the frame current identify the complete AW45 breaker?

No. Rated current, pole count, neutral rating, mounting type, controller, release supply and accessories also form part of the ordering configuration.

Are the 400 V and 690 V short-circuit ratings the same?

No. The comparison table lists separate values for each operating voltage.

Solicite un presupuesto

Crear una investigación clara.

Seleccione una serie y agregue los detalles eléctricos que el equipo de compras necesite confirmar.

Esta herramienta prepara el texto de la consulta. Copie el resumen y envíelo a través de nuestra página de contacto.

Contacte a CHSO →

No se envía ninguna solicitud automáticamente.

WhatsApp