Disyuntores de circuito eléctrico
Disyuntores de circuito de aire AW45
Compare 2000–6300 A frames for low-voltage switchboards. Select rated current, 3 or 4 poles, fixed or withdrawable construction, and the required controller and releases.
En una vista rápida
Especificaciones y comparación de modelos
- Corriente nominal
- 630–6300 A across listed frames
- Rated voltage
- 400 / 690 V AC
- Polacos
- 3P / 4P
- Frequency
- 50/60 Hz
- Mounting
- Fixed / withdrawable
- Temperatura ambiente
- −5 to +40 °C; 24 h average ≤35 °C
| Frame | Rated currents (A) | Icu 400 / 690 V (kA) | Ics = Icw 400 / 690 V (kA) | Solicitud |
|---|---|---|---|---|
| AW45-2000 | 630, 800, 1000, 1250, 1600, 2000 | 80 / 50 | 50 / 40 | Seleccione para RFQ → |
| AW45-3200 | 2000, 2500, 3200 | 100 / 65 | 80 / 50 | Seleccione para RFQ → |
| AW45-4000 | 2000, 2500, 3200, 4000 | 100 / 65 | 80 / 50 | Seleccione para RFQ → |
| AW45-6300 | 4000, 5000, 6300 | 120 / 80 | 100 / 65 | Seleccione para RFQ → |
Incluya en su solicitud el número de postes necesarios, la configuración eléctrica y los accesorios. Las descripciones de configuración no sustituyen al código completo de pedido.
Mechanical reference
Outline & mounting dimensions
Antes de ordenar
Especifica la configuración
- Specify the frame and rated current separately. Choose 3P or 4P and the neutral rating (50% In or 100% In) for the selected configuration.
- Select fixed or withdrawable construction and match the panel cut-out, busbar arrangement and mounting drawing.
- Specify the standard M controller or H communication controller, and required long-delay, short-delay, instantaneous and earth-fault protection settings.
- For shunt release, undervoltage release and closing electromagnet, state the required supply: AC 220 V, AC 380 V, DC 110 V or DC 220 V.
- Undervoltage release options include instantaneous and delayed operation (1, 3 or 5 s). Confirm auxiliary contact arrangement and energy-storage motor configuration.
- Installation altitude ≤2000 m; pollution degree III; install within 5° of vertical.
Preguntas de selección
Respondes prácticos a la compra
Does the frame current identify the complete AW45 breaker?
No. Rated current, pole count, neutral rating, mounting type, controller, release supply and accessories also form part of the ordering configuration.
Are the 400 V and 690 V short-circuit ratings the same?
No. The comparison table lists separate values for each operating voltage.
Solicite un presupuesto
Crear una investigación clara.
Seleccione una serie y agregue los detalles eléctricos que el equipo de compras necesite confirmar.
Esta herramienta prepara el texto de la consulta. Copie el resumen y envíelo a través de nuestra página de contacto.
Contacte a CHSO →