Wenzhou Changsong Electric Co., Ltd.
Catálogos e arquivos técnicosContato e perguntasWhatsApp
CHSOELETRICIDADE INDUSTRIALSolicite um orçamento 0→
Início/Proteção e Poder/Disjuntores/AW45

Air circuit breakers

AW45 Air Circuit Breakers

Compare 2000–6300 A frames for low-voltage switchboards. Select rated current, 3 or 4 poles, fixed or withdrawable construction, and the required controller and releases.

AW45 Air Circuit Breakers — series reference view
Referência da série • a configuração varia de acordo com o modelo

Em uma olhada

Especificações e comparação de modelos

Rated current
630–6300 A across listed frames
Rated voltage
400 / 690 V AC
Poles
3P / 4P
Frequency
50/60 Hz
Mounting
Fixed / withdrawable
Temperatura ambiente
−5 to +40 °C; 24 h average ≤35 °C
AW45 Air Circuit Breakers — specification comparison
FrameRated currents (A)Icu 400 / 690 V (kA)Ics = Icw 400 / 690 V (kA)Inquérito
AW45-2000630, 800, 1000, 1250, 1600, 200080 / 5050 / 40Selecionar para RFQ →
AW45-32002000, 2500, 3200100 / 6580 / 50Selecionar para RFQ →
AW45-40002000, 2500, 3200, 4000100 / 6580 / 50Selecionar para RFQ →
AW45-63004000, 5000, 6300120 / 80100 / 65Selecionar para RFQ →

Inclua no seu pedido o número de postes necessários, a configuração elétrica e os acessórios. As descrições das configurações não substituem o código de pedido completo.

Mechanical reference

Outline & mounting dimensions

AW45-2000 outline and mounting dimensions in millimetres
Dimensions in mm. Match the frame and configuration shown. Open full-size drawing ↗
AW45-3200 outline and mounting dimensions in millimetres
Dimensions in mm. Match the frame and configuration shown. Open full-size drawing ↗
AW45-LARGE outline and mounting dimensions in millimetres
Dimensions in mm. Match the frame and configuration shown. Open full-size drawing ↗

Antes de fazer o pedido

Especificar a configuração

  1. Specify the frame and rated current separately. Choose 3P or 4P and the neutral rating (50% In or 100% In) for the selected configuration.
  2. Select fixed or withdrawable construction and match the panel cut-out, busbar arrangement and mounting drawing.
  3. Specify the standard M controller or H communication controller, and required long-delay, short-delay, instantaneous and earth-fault protection settings.
  4. For shunt release, undervoltage release and closing electromagnet, state the required supply: AC 220 V, AC 380 V, DC 110 V or DC 220 V.
  5. Undervoltage release options include instantaneous and delayed operation (1, 3 or 5 s). Confirm auxiliary contact arrangement and energy-storage motor configuration.
  6. Installation altitude ≤2000 m; pollution degree III; install within 5° of vertical.

Questões de seleção

Respostas práticas para compras

Does the frame current identify the complete AW45 breaker?

No. Rated current, pole count, neutral rating, mounting type, controller, release supply and accessories also form part of the ordering configuration.

Are the 400 V and 690 V short-circuit ratings the same?

No. The comparison table lists separate values for each operating voltage.

Solicite um orçamento

Crie uma pesquisa clara.

Escolha uma série e adicione os detalhes elétricos que a sua equipe de compras precisa confirmar.

Esta ferramenta prepara o texto do pedido de informação. Copie o resumo e envie-o através da nossa página de contacto.

Contate a CHSO →

Nenhuma consulta é enviada automaticamente.

WhatsApp