
DT(G) Copper Cable Lugs
10–800 mm² · T2 copper · Bolted palm
Copper ring lugs for bolted cable terminations, covering 10–800 mm². Select by conductor section, barrel bore and stud-hole diameter.
Modelos e dimensões →From conductor to contact.
Every dimension matters.
Explore copper, aluminium and bimetallic cable lugs, straight connecting sleeves and C-type tap connectors. Compare materials, barrel sizes, mounting dimensions and construction before choosing a model.
Explore a gama ↓
Search an exact series or size, such as SC(JGB)-50, DTL-2-120 or GTY-240. Open a series to compare its model dimensions and original geometry drawing.
25 product series

10–800 mm² · T2 copper · Bolted palm
Copper ring lugs for bolted cable terminations, covering 10–800 mm². Select by conductor section, barrel bore and stud-hole diameter.
Modelos e dimensões →
10–800 mm² · T2 copper · Bolted palm
Compact T2 copper tube lugs with a tinned finish. JG provides a shorter overall length than the corresponding DT(G) size in this range.
Modelos e dimensões →
1.5–1000 mm² · T2 copper · Bolted palm
Tinned copper lugs with an inspection opening at the palm-to-barrel transition. Multiple stud-hole options cover 1.5–1000 mm² cable sizes.
Modelos e dimensões →
1.5–1000 mm² · T2 copper · Bolted palm
Tinned copper lugs with a flared cable entry. The widened mouth assists conductor insertion while the listed bore defines the crimp barrel.
Modelos e dimensões →
1.5–1000 mm² · T2 copper · Bolted palm
Tinned copper compression lugs with their own overall-length schedule. Compare the JGK dimensions directly when replacing another SC-style terminal.
Modelos e dimensões →
1.5–1000 mm² · T2 copper · Bolted palm
Tinned copper tube lugs with a compact palm transition and multiple mounting-hole choices. A wide 1.5–1000 mm² range supports panel and power-cable terminations.
Modelos e dimensões →
1.5–500 mm² · T2 copper · Bolted palm
Extended copper tube lugs for applications requiring a longer termination body. Compare barrel dimensions and available mounting space before choosing the long version.
Modelos e dimensões →
1.5–1000 mm² · T2 copper · Compression connection
Straight copper compression sleeves for joining copper conductors end to end. GTY combines small and large sizes in one 1.5–1000 mm² selection table.
Modelos e dimensões →
OT-10A to OT-1000A · Copper · Bolted palm
Open-barrel copper terminals with a ring palm for bolted distribution connections. The open wings require a crimp tool and profile suited to this construction.
Modelos e dimensões →
16–500 mm² · Copper / aluminium · Compression connection
Friction-welded copper–aluminium sleeves for transition joints between copper and aluminium conductors. Different bores accommodate the two sides of the joint.
Modelos e dimensões →
10–630 mm² · T2 copper · Compression connection
T2 copper connecting tubes with a through bore, covering 10–630 mm². Suitable for planned straight joints where insertion depth is controlled during assembly.
Modelos e dimensões →
10–300 mm² · L3 aluminium · Compression connection
L3 aluminium connecting tubes for aluminium-to-aluminium straight cable joints. The through-bore construction supports 10–300 mm² size options.
Modelos e dimensões →
10–800 mm² · T2 copper · Bolted palm
Copper-bar cable lugs with a closed palm transition for distribution and equipment terminations. The table includes palm width and barrel length as well as the conductor bore.
Modelos e dimensões →
10–800 mm² · L3 aluminium · Bolted palm
L3 aluminium cable lugs for aluminium conductor terminations. Large barrel and palm dimensions should be checked against the equipment terminal and available clearance.
Modelos e dimensões →
25–240 mm² · T2 copper · Bolted palm
A 16 mm wide palm and 8 mm mounting hole provide a compact bolted connection. Choose the copper DT version for copper conductors.
Modelos e dimensões →
25–240 mm² · Copper / aluminium · Bolted palm
A 16 mm wide palm and 8 mm mounting hole provide a compact bolted connection. Choose the copper–aluminium DTL version for aluminium-to-copper terminations.
Modelos e dimensões →
10–800 mm² · Copper / aluminium · Bolted palm
Friction-welded lugs combine an aluminium barrel with a copper palm for aluminium cable connections to copper equipment terminals. The range covers 10–800 mm².
Modelos e dimensões →
10–300 mm² · Copper / aluminium · Bolted palm
Copper–aluminium compression lugs offered in round-palm and rectangular-palm versions. Each version has its own bore, mounting hole and overall-length schedule.
Modelos e dimensões →
10–1000 mm² · Aluminium · Compression connection
Aluminium compression tubes with dimension-specific size options. Compare bore, outer diameter and length together for a planned aluminium cable joint.
Modelos e dimensões →
16–300 mm² · Aluminium · Bolted palm
Aluminium ring lugs with AU size designations, covering 16–300 mm². The dimensional table links the conductor bore to stud-hole and barrel-length requirements.
Modelos e dimensões →
6–1000 mm² · T2 copper · Bolted palm
Tinned copper tube lugs in the AUS dimensional series. The 6–1000 mm² range includes alternative stud-hole sizes and a defined overall-length schedule.
Modelos e dimensões →
6–1000 mm² · T2 copper · Compression connection
Tinned copper sleeves for straight copper conductor joints in the AUS dimensional range. Select the sleeve bore and length for the conductor and intended crimp system.
Modelos e dimensões →
35–240 mm² · Copper / aluminium · Bolted palm
Aluminium cable lugs with a copper insert at the bolted contact face. This construction provides a copper contact interface for an aluminium conductor termination.
Modelos e dimensões →
7.5–700 mm² selection bands · Copper · Compression connection
C-shaped copper compression clamps for copper-wire splicing. Model selection uses the specified conductor-section band and the clamp geometry.
Modelos e dimensões →
12 connection sizes · Copper · Compression connection
C-shaped copper tap connectors selected by paired conductor cross-sections. The combination table distinguishes supported size pairs from the overall clamp dimensions.
Modelos e dimensões →No matching series. Try a shorter model code or clear the type filter.
| Connection need | Famílias de produtos | Selection priority |
|---|---|---|
| Copper cable to a bolted terminal | DT(G), JG, SC, DT, AUS, OT | Conductor section, bore, stud hole and palm clearance |
| Aluminium cable to a compatible terminal | DL, DIN DL / AU | Aluminium conductor fit and equipment contact material |
| Aluminium cable to a copper terminal | DTL-1, DTL-2, narrow-palm DTL, AL-CU | Transition construction and Cu/Al orientation |
| Straight copper-to-copper joint | GTY, GT-1, AUS-TUBE | Both conductor ends, bore and joint length |
| Straight aluminium joint or Cu/Al transition | GL-1, DIN GL, GTL | Same-metal sleeve or bimetallic transition |
| Copper-wire tap / splice | CCT, CCA | Conductor section band or specified conductor pair |
Record copper or aluminium, nominal section and strand class. Fine-stranded, compacted and sector-shaped conductors can require different barrel or preparation choices.
For a lug, match the hole and palm to the equipment terminal. For a sleeve or tap, identify both conductors and the space available for the finished joint and insulation.
Select the connector, tool and die as a compatible system. Plan surface preparation, compression sequence, cable support and final joint protection.
A cable lug terminates a conductor with a palm or ring that bolts to an equipment terminal or busbar. A compression connector joins conductors directly and normally has no bolted palm.
Copper lugs terminate copper cables. Aluminium lugs terminate aluminium cables at a compatible interface. Bimetallic lugs combine an aluminium cable barrel with a copper contact section for an aluminium-to-copper transition.
Match conductor cross-section and strand construction to the barrel, then check stud-hole diameter, palm width and thickness, overall length and cable bending space. A similar model name does not guarantee identical dimensions.
No. SC(JGY), SC(JGB), SC(JGK), SC(JGA) and extended SC versions differ in entry shape, palm transition or length. Use the dimensions for the exact construction.
No. Nominal cable cross-section and a model suffix do not determine a universal continuous-current rating. The cable, connection, installation and operating temperature must be assessed together.
Provide series, conductor size and material, strand class, stud-hole diameter or conductor pair, quantities, finish and packaging. For DTL-2, identify round or rectangular palm; for narrow-palm lugs, specify that construction.
Include series and model, conductor material and size, stud-hole or joint requirements, quantities and packaging needs.