Aluminium lugs

DL Aluminium Cable Lugs

L3 aluminium cable lugs for aluminium conductor terminations. Large barrel and palm dimensions should be checked against the equipment terminal and available clearance.

10–800 mm²L3 aluminiumBolted palm
DL Aluminium Cable Lugs
DL · Aluminium lugs
Technical data

Material, connection & construction

DL product specifications
ParameterSpecification
SérieDL
Product formAluminium Cable Lugs
Conductor / interfaceAluminium conductor to aluminium-compatible equipment terminal
Body materialL3 aluminium
Size range10–800 mm²
Connection methodCrimped barrel with bolted palm
InsulationNon-insulated; provide application-specific joint insulation and enclosure protection
DimensionsMillimetres; conductor cross-section in mm²
Model selection

Models & dimensions

All dimensional values are in millimetres. Conductor sizes are in mm². Use the symbols in the drawing for the selected construction.

DL Aluminium Cable Lugs construction
Product construction
DL Aluminium Cable Lugs dimension symbols
Dimensional geometry · All dimensions in mm
Use the dimension symbols in this series drawing; symbols can differ between constructions.

DL model dimensions
ModeloStud hole ØBarrel OD DBarrel ID dOverall length LBarrel length L1
DL-108.5966828
DL-168.51067030
DL-258.51277534
DL-3510.5148.58538
DL-5010.5169.89040
DL-7012.51811.510248
DL-9512.52113.511251
DL-12014.5231512053
DL-15014.52516.512656
DL-18516.52718.513358
DL-24016.5302114060
DL-30021342416065
DL-40021382617070
DL-50021472919075
DL-63021543522085
DL-800216038250100
Application & installation

Select the complete connection

Application fit

  • Aluminium feeder terminations in distribution equipment
  • Bolted connections with an aluminium-compatible contact interface
  • Replacement lugs selected by bore, palm and mounting geometry

Ordering checklist

Specify DL construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

Installation sequence

  1. Isolate the circuit and verify that it is de-energised. Identify the conductor material, section and strand construction.
  2. Select the matching connector, tool and die combination. Strip to the required insertion length without cutting or losing strands.
  3. Prepare the aluminium contact surface and apply the joint compound specified by the connection system. Keep compound and preparation appropriate to each metal.
  4. Insert the conductor fully and crimp in the sequence and number of compressions specified for the connector/tool system. Do not substitute a die solely because its size marking looks similar.
  5. Place the palm flat against the intended terminal, use matching hardware and tighten to the equipment connection specification. Support the cable so the palm carries no avoidable bending load.
  6. Inspect the compression, conductor retention and contact alignment. Restore suitable insulation and protection, then carry out the assembly checks before energising.
Respostas práticas

Perguntas frequentes

What distinguishes DL from other cable connectors?

L3 aluminium cable lugs for aluminium conductor terminations. Large barrel and palm dimensions should be checked against the equipment terminal and available clearance.

How do I select the correct DL size?

Specify DL construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

Does the conductor size determine a universal current rating?

No. Connection current depends on the cable material and size, insulation temperature, terminal interface, installation conditions and verified crimp system. Select the whole circuit and connection together.

Can I use any crimping die with the same size number?

No. Die profile, tool force, connector wall thickness and conductor construction work as a system. Use the specified tool/die combination for the chosen connector.

Is the model size the same as the stud-hole diameter?

No. The conductor size identifies the cable section, while the hole dimension identifies the bolted interface. Both must suit the application.

Inquéritos de distribuidores e montadores de painéis

Specify the conductor.
Match the connection.

Include DL model and construction, conductor material and size, stud-hole or joint requirements, quantities and packaging needs.

Solicite cotação ↗