TB Fixed Terminal Blocks
Compare fixed TB terminal strips from 15 A to 100 A. Each explicit model or listed pole configuration has a separate selection row, with shared-caption dimensions clearly marked for confirmation.

Understand the series.
| Catalogue current classes | 15 / 25 / 35 / 45 / 60 / 100 A |
|---|---|
| Catalogue voltage | 600 V |
| Conductor data | Ranges are listed by model group |
| Dimension convention | Overall L × W × H in millimetres; no mounting centres are inferred |
Check the selected reference.
Search a model or choose a section. A model link opens its corresponding catalogue illustration; shared range images are identified by their captions.
29 models / configurations
No matching model. Clear the filters or try a shorter reference.
15 A to 45 A models
| CHSO model | Section mm² | Current A | Voltage V | L mm | W mm | H mm |
|---|---|---|---|---|---|---|
| TB-1503 | 0.5–1.5 | 15 | 600 | 45.5 | 22 | 17.5 |
| TB-1504 | 0.5–1.5 | 15 | 600 | 54.2 | 22 | 17.5 |
| TB-1505 | 0.5–1.5 | 15 | 600 | 63 | 22 | 17.5 |
| TB-1506 | 0.5–1.5 | 15 | 600 | 73 | 22 | 17.5 |
| TB-1510 | 0.5–1.5 | 15 | 600 | 107.5 | 22 | 17.5 |
| TB-1512 | 0.5–1.5 | 15 | 600 | 125.5 | 22 | 17.5 |
| TB-2503 | 0.5–2.5 | 25 | 600 | 55 | 30 | 19 |
| TB-2504 | 0.5–2.5 | 25 | 600 | 67 | 30 | 19 |
| TB-2505 | 0.5–2.5 | 25 | 600 | 79 | 30 | 19 |
| TB-2506 | 0.5–2.5 | 25 | 600 | 91 | 30 | 19 |
| TB-2510 | 0.5–2.5 | 25 | 600 | 165* | 30 | 19 |
| TB-2512 | 0.5–2.5 | 25 | 600 | 163* | 30 | 19 |
| TB-3503 | 0.5–2.5 | 35 | 600 | 55 | 30 | 19 |
| TB-3504 | 0.5–2.5 | 35 | 600 | 67 | 30 | 19 |
| TB-3506 | 0.5–2.5 | 35 | 600 | 91 | 30 | 19 |
| TB-3512 | 0.5–2.5 | 35 | 600 | 165 | 30 | 19 |
| TB-4503 | 1.5–4 | 45 | 600 | 70 | 38 | 23.5 |
| TB-4504 | 1.5–4 | 45 | 600 | 86 | 38 | 23.5 |
| TB-4505 | 1.5–4 | 45 | 600 | 103 | 38 | 23.5 |
| TB-4506 | 1.5–4 | 45 | 600 | 120.5 | 38 | 23.5 |
| TB-4512 | 1.5–4 | 45 | 600 | 221 | 38 | 23.5 |
60 A and 100 A pole configurations
| CHSO model | Section mm² | Current A | Voltage V | Поляки | L mm | W mm | H mm |
|---|---|---|---|---|---|---|---|
| TB-60A/3P | 2.5–6 | 60 | 600 | 3 | 75 | 38 | 30.3 |
| TB-60A/4P | 2.5–6 | 60 | 600 | 4 | Confirm | Confirm | Confirm |
| TB-60A/6P | 2.5–6 | 60 | 600 | 6 | Confirm | Confirm | Confirm |
| TB-60A/12P | 2.5–6 | 60 | 600 | 12 | Confirm | Confirm | Confirm |
| TB-100A/3P | 2.5–10 | 100 | 600 | 3 | Confirm | Confirm | Confirm |
| TB-100A/4P | 2.5–10 | 100 | 600 | 4 | Confirm | Confirm | Confirm |
| TB-100A/6P | 2.5–10 | 100 | 600 | 6 | Confirm | Confirm | Confirm |
| TB-100A/12P | 2.5–10 | 100 | 600 | 12 | Confirm | Confirm | Confirm |
Catalogue notes & confirmation points
- TB-2510 and TB-2512 are printed with lengths of 165 mm and 163 mm respectively. These catalogue values are retained with a note to confirm the correct drawing.
- The shared TB-60A/4P, 6P, 12P caption lists 92.7 × 38 × 30 mm without assigning it to every pole count. Those configurations are marked Confirm for dimensions.
- The shared TB-100A/3P, 4P, 6P, 12P caption lists 86.3 × 43.5 × 34.5 mm. It is not applied to every pole count; request the selected configuration's drawing.
Review the physical format.
Open the original catalogue illustrations. Dimensions are millimetres unless the drawing indicates otherwise. Model captions on this page use CHSO order references.
TB-2503 product view

TB-1503 product view

TB-1504 product view

TB-1505 product view

TB-1506 product view

TB-1510 product view

TB-1512 product view

TB-2504 product view

TB-2505 product view

TB-2506 product view

TB-2510 product view

TB-2512 product view

TB-3503 product view

TB-3504 product view

TB-3506 product view

TB-3512 product view

TB-4503 product view

TB-4504 product view

TB-4505 product view

TB-4506 product view

TB-4512 product view

TB-60A/3P product view

Shared TB-60A 4P / 6P / 12P illustration

Shared TB-100A 3P / 4P / 6P / 12P illustration

Specify the complete configuration.
- TB model and pole count
- Conductor type, section and circuit duty
- Verified overall and mounting dimensions, quantities and cover requirements
- Required drawing revision, installation instructions and compliance evidence
Before you specify.
What does the TB range cover?
Compare fixed TB terminal strips from 15 A to 100 A. Each explicit model or listed pole configuration has a separate selection row, with shared-caption dimensions clearly marked for confirmation.
Which details are needed to specify TB?
TB model and pole count. Conductor type, section and circuit duty. Verified overall and mounting dimensions, quantities and cover requirements.
Are all catalogue figures ready for final design?
TB-2510 and TB-2512 are printed with lengths of 165 mm and 163 mm respectively. These catalogue values are retained with a note to confirm the correct drawing. The shared TB-60A/4P, 6P, 12P caption lists 92.7 × 38 × 30 mm without assigning it to every pole count. Those configurations are marked Confirm for dimensions. The shared TB-100A/3P, 4P, 6P, 12P caption lists 86.3 × 43.5 × 34.5 mm. It is not applied to every pole count; request the selected configuration's drawing.
What documentation should I request for the selected model?
Request the approved dimensional drawing, installation instructions and any required material or compliance evidence for the exact order configuration. A general catalogue illustration or material grade is not a blanket certification of every finished model.
Specify your TB terminal list.
Send models, quantities, conductor details and the mounting arrangement. Include the accessories and documents your project requires.