Wenzhou Changsong Electric Co., Ltd.
Catálogos y ficheros técnicosContacto e indagaciónWhatsApp
CHSOELECTRÓNICA INDUSTRIALSolicite un presupuesto 0→
Conector de cobre

Tugos de cable de compresión de cobre DT

Conectores de cable de barra de cobre con transición de palma cerrada para conexiones de distribución y equipos. La tabla incluye la anchura de la palma y la longitud del barril, así como el diámetro del conductor.

10–800 mm²T2 copperBolted palm
DT Copper Compression Cable Lugs
DT · Copper lugs
Datos técnicos

Material, connection & construction

DT product specifications
ParámetroEspecificaciones
SerieDT
Product formCopper Compression Cable Lugs
Conductor / interfaceCopper conductor to bolted equipment terminal
Body materialT2 copper
Size range10–800 mm²
Connection methodCrimped barrel with bolted palm
InsulationNon-insulated; provide application-specific joint insulation and enclosure protection
DimensionsMillimetres; conductor cross-section in mm²
Finish optionsBare copper / tinned copper; specify the required finish
Selección del modelo

Modelos y dimensiones

All dimensional values are in millimetres. Conductor sizes are in mm². Use the symbols in the drawing for the selected construction.

DT and DT(G) are separate dimensional series. Match the full designation rather than treating the two as interchangeable.

DT Copper Compression Cable Lugs construction
Product construction
DT Copper Compression Cable Lugs dimension symbols
Dimensional geometry · All dimensions in mm
Use the dimension symbols in this series drawing; symbols can differ between constructions.

DT model dimensions
ModeloStud hole ØBarrel OD DBarrel ID dOverall length LBarrel length L1Palm width B
DT-108.595.3622816
DT-168.5106.5683016
DT-258.5117703318
DT-3510.5128.5803620.5
DT-5010.5149.5853823
DT-7012.51611.5954326
DT-9512.51813.51044628
DT-12014.520151124930
DT-15014.52216.51205134
DT-18516.52518.51255537
DT-24016.527211366040
DT-300183123.51556650
DT-400213426.51707550
DT-5002138291907560
DT-6302145352208580
DT-80021503826085100
Aplicación y instalación

Select the complete connection

Compatibilidad de la aplicación

  • Cable ends in power-distribution and control cabinets
  • Bolted connections to compatible copper busbars and equipment terminals
  • Replacement terminations where barrel, hole and palm dimensions match

Lista de verificación de pedidos

Specify DT construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

Secuencia de instalación

  1. Isolate the circuit and verify that it is de-energised. Identify the conductor material, section and strand construction.
  2. Select the matching connector, tool and die combination. Strip to the required insertion length without cutting or losing strands.
  3. Insert the conductor fully and crimp in the sequence and number of compressions specified for the connector/tool system. Do not substitute a die solely because its size marking looks similar.
  4. Place the palm flat against the intended terminal, use matching hardware and tighten to the equipment connection specification. Support the cable so the palm carries no avoidable bending load.
  5. Inspect the compression, conductor retention and contact alignment. Restore suitable insulation and protection, then carry out the assembly checks before energising.
Respondes de forma práctica

Preguntas frecuentes

What distinguishes DT from other cable connectors?

Conectores de cable de barra de cobre con transición de palma cerrada para conexiones de distribución y equipos. La tabla incluye la anchura de la palma y la longitud del barril, así como el diámetro del conductor.

How do I select the correct DT size?

Specify DT construction, conductor material and nominal section, conductor strand class, stud-hole diameter, palm clearance, tool/die system, quantity and required finish.

What should I check before ordering this series?

DT and DT(G) are separate dimensional series. Match the full designation rather than treating the two as interchangeable.

Does the conductor size determine a universal current rating?

No. Connection current depends on the cable material and size, insulation temperature, terminal interface, installation conditions and verified crimp system. Select the whole circuit and connection together.

Can I use any crimping die with the same size number?

No. Die profile, tool force, connector wall thickness and conductor construction work as a system. Use the specified tool/die combination for the chosen connector.

Is the model size the same as the stud-hole diameter?

No. The conductor size identifies the cable section, while the hole dimension identifies the bolted interface. Both must suit the application.

Consultas de distribuidores y constructores de paneles

Especifica el conductor.
Conecte la conexión.

Include DT model and construction, conductor material and size, stud-hole or joint requirements, quantities and packaging needs.

Solicite un presupuesto ↗