Barras terminales neutras

CS035-1218 Barra de terminal principal y de subestación

CS035-1218 barra de terminal común de latón con conexión principal más grande y múltiples conexiones de derivación en una base de montaje aislada.

Main + branch connectionsM8 main screwM5 branch screws
CS035-1218 Main-and-Branch Terminal Bar
CS035-1218 · Neutral Terminal Bars
Datos técnicos

Especificaciones del producto

CS035-1218 technical specifications
ParámetroEspecificaciones
SerieCS035-1218
Terminal materialBrass
Insulating supportPA nylon
MountingScrew-mounted base
Main clamping screwM8 × 15
Branch clamping screwM5 × 10
Branch bore diameter6.5 mm
Branch pitch8 mm
Overall width42 mm
Transverse fixing centres33 mm
Connections & dimensions

Choose the connection-position configuration

CS035-1218 selection table
Main + branch positionsLongitudinal fixing centres (mm)Overall length (mm)
1 + 465.779.7
1 + 897.7111.7
1 + 12129.7143.7
1 + 16161.7175.7
1 + 24225.7239.7
1 + 48417.7431.7

Additional base-length option

CS035-1218 — Additional base-length option
Overall length (mm)Longitudinal fixing centres (mm)Width (mm)
303.7289.742
Mechanical layout

Dimensional drawing

Dimensions in millimetres. Compare the drawing with the option table when selecting a length or connection-position count.

CS035-1218 dimensional drawing in millimetres
Aplicación y instalación

Select for the complete panel

Use the larger main connection for the feeder and the smaller entries for branches at the same potential. Select branch count and base length together; provide support for the incoming cable independently of the terminal bar.

Compatibilidad de la aplicación

  • Multi-branch common-potential distribution
  • Extended neutral rows inside enclosed distribution equipment

Secuencia de instalación

  1. Isolate the circuit and verify that it is de-energised.
  2. Secure the terminal assembly to the matching rail or mounting surface. Keep accessible metal parts separated from other potentials.
  3. Prepare conductors for full engagement in the clamp, without damaged strands or exposed copper outside the entry.
  4. Use the clamping screw appropriate to the entry; support wires so that cable tension is not carried by the terminal.
  5. Check conductor retention, circuit identification and continuity. Close any fitted cover before energising the completed assembly.
Respondes de forma práctica

Preguntas frecuentes

Are the main and branch entries isolated?

No. They connect to one continuous brass bar and share the same potential.

Why are the main and branch screws different?

The main connection uses an M8 × 15 screw; the smaller branch entries use M5 × 10 screws. Screw dimensions are not current ratings.